0 [11/06/08 08:58:49:921]: EIB connection established
1 [11/06/08 08:59:47:531]: GroupDataConfirmationRead: 04/0001, RoutingCnt=6, PriorityLow, No Error
2 [11/06/08 08:59:47:531]: GroupDataConfirmationRead: 06/0801, RoutingCnt=6, PriorityLow, No Error
3 [11/06/08 08:59:47:562]: GroupDataIndicationResponse: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x00', Soire rception ON/OFF: off
4 [11/06/08 08:59:47:562]: GroupDataIndicationResponse: 01.01.007, 06/0801, RoutingCnt=6, PriorityLow, Data='0xFF', Info d'tat variation % lampe repas: 100
5 [11/06/08 08:59:47:890]: GroupDataConfirmationRead: 06/0001, RoutingCnt=6, PriorityLow, No Error
6 [11/06/08 08:59:47:890]: GroupDataIndicationResponse: 01.01.007, 06/0001, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes hall et repas: on
7 [11/06/08 08:59:47:953]: GroupDataIndicationResponse: 01.01.011, 06/0001, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes hall et repas: off
8 [11/06/08 08:59:47:953]: GroupDataIndicationResponse: 01.01.002, 06/0001, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes hall et repas: off
9 [11/06/08 08:59:47:953]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat  ON/OFF lampes hall et repas: on
10 [11/06/08 08:59:48:015]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat  ON/OFF lampes hall et repas: off
11 [11/06/08 08:59:48:390]: GroupDataConfirmationRead: 09/0202, RoutingCnt=6, PriorityLow, No Error
12 [11/06/08 08:59:48:390]: GroupDataIndicationResponse: 01.01.003, 09/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Ventouse lectromagntique: off
13 [11/06/08 08:59:48:890]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Hall: 2.00 W
14 [11/06/08 08:59:48:890]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
15 [11/06/08 08:59:48:890]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
16 [11/06/08 08:59:48:890]: GroupDataConfirmationRead: 07/0002, RoutingCnt=6, PriorityLow, No Error
17 [11/06/08 08:59:48:890]: GroupDataIndicationResponse: 01.01.004, 07/0002, RoutingCnt=6, PriorityLow, Data='0x00', Dfaut vent ON/OFF: off
18 [11/06/08 08:59:49:390]: GroupDataConfirmationRead: 07/0003, RoutingCnt=6, PriorityLow, No Error
19 [11/06/08 08:59:49:390]: GroupDataIndicationResponse: 01.01.002, 06/0001, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes hall et repas: off
20 [11/06/08 08:59:49:765]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
21 [11/06/08 08:59:49:890]: GroupDataConfirmationRead: 09/0001, RoutingCnt=6, PriorityLow, No Error
22 [11/06/08 08:59:49:921]: GroupDataIndicationResponse: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', Sonnerie ON/OFF: off
23 [11/06/08 08:59:50:390]: GroupDataConfirmationRead: 09/0002, RoutingCnt=6, PriorityLow, No Error
24 [11/06/08 08:59:50:453]: GroupDataIndicationResponse: 01.01.011, 09/0002, RoutingCnt=6, PriorityLow, Data='0x00', Ventouse lectromagntique ON/OFF: off
25 [11/06/08 08:59:50:890]: GroupDataConfirmationRead: 13/0801, RoutingCnt=6, PriorityLow, No Error
26 [11/06/08 08:59:50:890]: GroupDataIndicationResponse: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat % position store letrique: 0
27 [11/06/08 08:59:51:390]: GroupDataConfirmationRead: 13/0001, RoutingCnt=6, PriorityLow, No Error
28 [11/06/08 08:59:51:453]: GroupDataIndicationResponse: 01.01.011, 13/0001, RoutingCnt=6, PriorityLow, Data='0x00', Monter/Descendre Store: off
29 [11/06/08 08:59:51:890]: GroupDataConfirmationRead: 13/0002, RoutingCnt=6, PriorityLow, No Error
30 [11/06/08 08:59:51:953]: GroupDataIndicationResponse: 01.01.011, 13/0002, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison/Stop store: off
31 [11/06/08 08:59:52:390]: GroupDataConfirmationRead: 06/0202, RoutingCnt=6, PriorityLow, No Error
32 [11/06/08 08:59:52:390]: GroupDataIndicationResponse: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
33 [11/06/08 08:59:52:890]: GroupDataConfirmationRead: 06/0203, RoutingCnt=6, PriorityLow, No Error
34 [11/06/08 08:59:52:890]: GroupDataIndicationResponse: 01.01.002, 06/0203, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampe SAS: off
35 [11/06/08 08:59:55:765]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
36 [11/06/08 08:59:55:828]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
37 [11/06/08 08:59:59:703]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
38 [11/06/08 08:59:59:765]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
39 [11/06/08 09:00:00:640]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x41 0xE8 0x00 0x00', Puissance Hall: 29.00 W
40 [11/06/08 09:00:00:640]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xEB 0xA0 0x00', Puissance Chambre: 1885.00 W
41 [11/06/08 09:00:00:718]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x04 0x00 0x00', Puissance Extrieur: 33.00 W
42 [11/06/08 09:00:01:953]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
43 [11/06/08 09:00:02:015]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
44 [11/06/08 09:00:03:703]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
45 [11/06/08 09:00:09:703]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
46 [11/06/08 09:00:12:578]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Hall: 2.00 W
47 [11/06/08 09:00:12:578]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
48 [11/06/08 09:00:12:640]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
49 [11/06/08 09:00:13:640]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
50 [11/06/08 09:00:15:828]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
51 [11/06/08 09:00:15:890]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
52 [11/06/08 09:00:19:640]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x04', Temprature chambre: 20.80 C
53 [11/06/08 09:00:24:578]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
54 [11/06/08 09:00:24:578]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
55 [11/06/08 09:00:24:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
56 [11/06/08 09:00:25:578]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
57 [11/06/08 09:00:27:578]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x05', Temprature chambre: 20.88 C
58 [11/06/08 09:00:28:015]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x15 0x33', Luminosit: 53.24 Lux
59 [11/06/08 09:00:30:015]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
60 [11/06/08 09:00:35:203]: GroupDataConfirmationWrite: 04/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Soire rception ON/OFF: on
61 [11/06/08 09:00:35:265]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir chambre: on
62 [11/06/08 09:00:36:515]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
63 [11/06/08 09:00:36:578]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
64 [11/06/08 09:00:36:578]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
65 [11/06/08 09:00:47:515]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x04', Temprature chambre: 20.80 C
66 [11/06/08 09:00:48:453]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
67 [11/06/08 09:00:48:453]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Chambre: 99.00 W
68 [11/06/08 09:00:48:515]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
69 [11/06/08 09:01:00:390]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
70 [11/06/08 09:01:00:453]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Chambre: 99.00 W
71 [11/06/08 09:01:00:453]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
72 [11/06/08 09:01:02:453]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
73 [11/06/08 09:01:02:453]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
74 [11/06/08 09:01:07:390]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
75 [11/06/08 09:01:12:328]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Hall: 99.00 W
76 [11/06/08 09:01:12:390]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Chambre: 99.00 W
77 [11/06/08 09:01:12:390]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
78 [11/06/08 09:01:14:140]: GroupDataConfirmationWrite: 04/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Soire rception ON/OFF: off
79 [11/06/08 09:01:24:265]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Hall: 99.00 W
80 [11/06/08 09:01:24:328]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Chambre: 99.00 W
81 [11/06/08 09:01:24:390]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
82 [11/06/08 09:01:28:640]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x15 0x69', Luminosit: 55.40 Lux
83 [11/06/08 09:01:29:328]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
84 [11/06/08 09:01:29:578]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
85 [11/06/08 09:01:29:578]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir chambre: off
86 [11/06/08 09:01:30:328]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
87 [11/06/08 09:01:30:328]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
88 [11/06/08 09:01:36:265]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
89 [11/06/08 09:01:36:343]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
90 [11/06/08 09:01:36:343]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
91 [11/06/08 09:01:38:953]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
92 [11/06/08 09:01:42:015]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
93 [11/06/08 09:01:45:515]: GroupDataConfirmationWrite: 04/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Soire rception ON/OFF: on
94 [11/06/08 09:01:45:578]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir chambre: on
95 [11/06/08 09:01:48:203]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
96 [11/06/08 09:01:48:265]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0x2C 0x00 0x00', Puissance Chambre: 43.00 W
97 [11/06/08 09:01:48:265]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
98 [11/06/08 09:01:50:078]: GroupDataConfirmationRead: 07/0003, RoutingCnt=6, PriorityLow, No Error
99 [11/06/08 09:01:50:078]: GroupDataIndicationResponse: 01.01.002, 06/0001, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes hall et repas: off
100 [11/06/08 09:01:57:203]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
101 [11/06/08 09:01:57:203]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
102 [11/06/08 09:01:59:140]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
103 [11/06/08 09:01:59:453]: GroupDataConfirmationWrite: 04/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Soire rception ON/OFF: off
104 [11/06/08 09:02:00:140]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Hall: 99.00 W
105 [11/06/08 09:02:00:203]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Chambre: 99.00 W
106 [11/06/08 09:02:00:203]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
107 [11/06/08 09:02:02:828]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
108 [11/06/08 09:02:02:828]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
109 [11/06/08 09:02:12:078]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Hall: 99.00 W
110 [11/06/08 09:02:12:140]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Chambre: 99.00 W
111 [11/06/08 09:02:12:156]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
112 [11/06/08 09:02:14:390]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir chambre: off
113 [11/06/08 09:02:14:390]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
114 [11/06/08 09:02:15:015]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
115 [11/06/08 09:02:15:078]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
116 [11/06/08 09:02:24:078]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
117 [11/06/08 09:02:24:140]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
118 [11/06/08 09:02:24:218]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
119 [11/06/08 09:02:25:140]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
120 [11/06/08 09:02:29:265]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x15 0x78', Luminosit: 56.00 Lux
121 [11/06/08 09:02:33:015]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
122 [11/06/08 09:02:33:578]: GroupDataConfirmationWrite: 13/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Monter/Descendre Store: off
123 [11/06/08 09:02:34:828]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
124 [11/06/08 09:02:36:078]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xFE 0x00 0x00', Puissance Hall: 127.00 W
125 [11/06/08 09:02:36:156]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
126 [11/06/08 09:02:36:156]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
127 [11/06/08 09:02:43:703]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
128 [11/06/08 09:02:44:890]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat % inclinaison lamelles: 0
129 [11/06/08 09:02:44:890]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat % position store letrique: 0
130 [11/06/08 09:02:48:015]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
131 [11/06/08 09:02:48:093]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
132 [11/06/08 09:02:48:093]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
133 [11/06/08 09:02:50:640]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
134 [11/06/08 09:02:51:453]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
135 [11/06/08 09:02:51:515]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
136 [11/06/08 09:02:54:828]: GroupDataConfirmationWrite: 13/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Monter/Descendre Store: on
137 [11/06/08 09:02:58:515]: GroupDataConfirmationWrite: 13/0002, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Inclinaison/Stop store: on
138 [11/06/08 09:02:59:578]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0xFF', Info d'tat % inclinaison lamelles: 100
139 [11/06/08 09:02:59:640]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0x5D', Info d'tat % position store letrique: 36
140 [11/06/08 09:03:00:015]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x3E 0x00 0x00', Puissance Hall: 190.00 W
141 [11/06/08 09:03:00:015]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
142 [11/06/08 09:03:00:078]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Extrieur: 2.00 W
143 [11/06/08 09:03:00:765]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
144 [11/06/08 09:03:00:890]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFD', Temprature chambre: 20.24 C
145 [11/06/08 09:03:02:890]: GroupDataConfirmationWrite: 13/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Monter/Descendre Store: on
146 [11/06/08 09:03:03:015]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
147 [11/06/08 09:03:03:203]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
148 [11/06/08 09:03:03:265]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
149 [11/06/08 09:03:06:515]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat % inclinaison lamelles: 0
150 [11/06/08 09:03:06:515]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0x4D', Info d'tat % position store letrique: 30
151 [11/06/08 09:03:08:828]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
152 [11/06/08 09:03:10:828]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
153 [11/06/08 09:03:10:890]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
154 [11/06/08 09:03:12:015]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
155 [11/06/08 09:03:12:015]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
156 [11/06/08 09:03:12:093]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
157 [11/06/08 09:03:17:515]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
158 [11/06/08 09:03:18:453]: GroupDataConfirmationWrite: 13/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Monter/Descendre Store: on
159 [11/06/08 09:03:20:765]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
160 [11/06/08 09:03:20:828]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
161 [11/06/08 09:03:24:015]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x4C 0x00 0x00', Puissance Hall: 204.00 W
162 [11/06/08 09:03:24:015]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0x37 0x40 0x00', Puissance Chambre: 733.00 W
163 [11/06/08 09:03:24:015]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x60 0x00 0x00', Puissance Extrieur: 14.00 W
164 [11/06/08 09:03:24:890]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
165 [11/06/08 09:03:25:578]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0xFF', Info d'tat % inclinaison lamelles: 100
166 [11/06/08 09:03:25:578]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0xFF', Info d'tat % position store letrique: 100
167 [11/06/08 09:03:28:765]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
168 [11/06/08 09:03:29:890]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x15 0x65', Luminosit: 55.24 Lux
169 [11/06/08 09:03:35:000]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
170 [11/06/08 09:03:35:953]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
171 [11/06/08 09:03:36:015]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
172 [11/06/08 09:03:36:015]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
173 [11/06/08 09:03:38:703]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
174 [11/06/08 09:03:39:750]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
175 [11/06/08 09:03:40:312]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
176 [11/06/08 09:03:40:312]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
177 [11/06/08 09:03:42:687]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x04', Temprature chambre: 20.80 C
178 [11/06/08 09:03:47:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
179 [11/06/08 09:03:48:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
180 [11/06/08 09:03:48:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
181 [11/06/08 09:03:49:000]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
182 [11/06/08 09:03:50:562]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
183 [11/06/08 09:03:51:062]: GroupDataConfirmationRead: 07/0003, RoutingCnt=6, PriorityLow, No Error
184 [11/06/08 09:03:51:062]: GroupDataIndicationResponse: 01.01.002, 06/0001, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes hall et repas: off
185 [11/06/08 09:03:59:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
186 [11/06/08 09:03:59:953]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
187 [11/06/08 09:04:00:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
188 [11/06/08 09:04:03:562]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
189 [11/06/08 09:04:03:625]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
190 [11/06/08 09:04:03:687]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0xFF', Info d'tat % inclinaison lamelles: 100
191 [11/06/08 09:04:03:750]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0xFF', Info d'tat % position store letrique: 100
192 [11/06/08 09:04:05:312]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
193 [11/06/08 09:04:05:812]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat % inclinaison lamelles: 0
194 [11/06/08 09:04:05:812]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0xE5', Info d'tat % position store letrique: 90
195 [11/06/08 09:04:05:937]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
196 [11/06/08 09:04:05:937]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
197 [11/06/08 09:04:12:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
198 [11/06/08 09:04:12:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
199 [11/06/08 09:04:12:062]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
200 [11/06/08 09:04:23:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
201 [11/06/08 09:04:23:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
202 [11/06/08 09:04:23:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
203 [11/06/08 09:04:30:562]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x15 0x47', Luminosit: 54.04 Lux
204 [11/06/08 09:04:35:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
205 [11/06/08 09:04:35:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
206 [11/06/08 09:04:35:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
207 [11/06/08 09:04:40:390]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
208 [11/06/08 09:04:47:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
209 [11/06/08 09:04:47:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
210 [11/06/08 09:04:47:968]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
211 [11/06/08 09:04:59:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
212 [11/06/08 09:04:59:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
213 [11/06/08 09:04:59:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
214 [11/06/08 09:05:04:062]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
215 [11/06/08 09:05:04:140]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
216 [11/06/08 09:05:08:250]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
217 [11/06/08 09:05:11:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
218 [11/06/08 09:05:11:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
219 [11/06/08 09:05:11:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
220 [11/06/08 09:05:18:218]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
221 [11/06/08 09:05:18:250]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
222 [11/06/08 09:05:23:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
223 [11/06/08 09:05:23:890]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
224 [11/06/08 09:05:23:890]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
225 [11/06/08 09:05:31:187]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x15 0x14', Luminosit: 52.00 Lux
226 [11/06/08 09:05:32:125]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
227 [11/06/08 09:05:35:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
228 [11/06/08 09:05:35:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
229 [11/06/08 09:05:35:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
230 [11/06/08 09:05:47:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
231 [11/06/08 09:05:47:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
232 [11/06/08 09:05:47:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
233 [11/06/08 09:05:52:062]: GroupDataConfirmationRead: 07/0003, RoutingCnt=6, PriorityLow, No Error
234 [11/06/08 09:05:52:062]: GroupDataIndicationResponse: 01.01.002, 06/0001, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes hall et repas: off
235 [11/06/08 09:05:56:062]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
236 [11/06/08 09:05:59:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
237 [11/06/08 09:05:59:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
238 [11/06/08 09:05:59:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
239 [11/06/08 09:06:04:437]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
240 [11/06/08 09:06:04:437]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
241 [11/06/08 09:06:05:062]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
242 [11/06/08 09:06:11:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
243 [11/06/08 09:06:11:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
244 [11/06/08 09:06:11:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
245 [11/06/08 09:06:23:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
246 [11/06/08 09:06:23:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
247 [11/06/08 09:06:23:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
248 [11/06/08 09:06:25:875]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFD', Temprature chambre: 20.24 C
249 [11/06/08 09:06:27:875]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
250 [11/06/08 09:06:27:953]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
251 [11/06/08 09:06:31:937]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x15 0x32', Luminosit: 53.20 Lux
252 [11/06/08 09:06:35:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xFE 0x00 0x00', Puissance Hall: 127.00 W
253 [11/06/08 09:06:35:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xEA 0x80 0x00', Puissance Chambre: 1876.00 W
254 [11/06/08 09:06:35:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x08 0x00 0x00', Puissance Extrieur: 34.00 W
255 [11/06/08 09:06:35:921]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
256 [11/06/08 09:06:35:937]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
257 [11/06/08 09:06:43:812]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
258 [11/06/08 09:06:47:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
259 [11/06/08 09:06:47:765]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
260 [11/06/08 09:06:47:765]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
261 [11/06/08 09:06:49:812]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
262 [11/06/08 09:06:53:750]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
263 [11/06/08 09:06:59:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
264 [11/06/08 09:06:59:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
265 [11/06/08 09:06:59:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
266 [11/06/08 09:07:03:687]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
267 [11/06/08 09:07:04:750]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
268 [11/06/08 09:07:04:812]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
269 [11/06/08 09:07:11:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
270 [11/06/08 09:07:11:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
271 [11/06/08 09:07:11:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
272 [11/06/08 09:07:23:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
273 [11/06/08 09:07:23:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
274 [11/06/08 09:07:23:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
275 [11/06/08 09:07:31:562]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
276 [11/06/08 09:07:32:500]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x15 0x41', Luminosit: 53.80 Lux
277 [11/06/08 09:07:35:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
278 [11/06/08 09:07:35:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
279 [11/06/08 09:07:35:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
280 [11/06/08 09:07:47:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
281 [11/06/08 09:07:47:703]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
282 [11/06/08 09:07:47:703]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
283 [11/06/08 09:07:59:437]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
284 [11/06/08 09:07:59:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
285 [11/06/08 09:07:59:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
286 [11/06/08 09:07:59:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
287 [11/06/08 09:08:05:187]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
288 [11/06/08 09:08:05:250]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
289 [11/06/08 09:08:05:437]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
290 [11/06/08 09:08:05:500]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
291 [11/06/08 09:08:09:375]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
292 [11/06/08 09:08:09:437]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
293 [11/06/08 09:08:11:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xFE 0x00 0x00', Puissance Hall: 127.00 W
294 [11/06/08 09:08:11:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xEA 0x40 0x00', Puissance Chambre: 1874.00 W
295 [11/06/08 09:08:11:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x08 0x00 0x00', Puissance Extrieur: 34.00 W
296 [11/06/08 09:08:23:312]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
297 [11/06/08 09:08:23:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
298 [11/06/08 09:08:23:640]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
299 [11/06/08 09:08:23:640]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
300 [11/06/08 09:08:33:125]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x15 0x76', Luminosit: 55.92 Lux
301 [11/06/08 09:08:35:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
302 [11/06/08 09:08:35:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
303 [11/06/08 09:08:35:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
304 [11/06/08 09:08:47:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
305 [11/06/08 09:08:47:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
306 [11/06/08 09:08:47:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
307 [11/06/08 09:08:54:500]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
308 [11/06/08 09:08:59:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
309 [11/06/08 09:08:59:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
310 [11/06/08 09:08:59:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
311 [11/06/08 09:09:03:187]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
312 [11/06/08 09:09:05:687]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
313 [11/06/08 09:09:05:687]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
314 [11/06/08 09:09:11:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
315 [11/06/08 09:09:11:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
316 [11/06/08 09:09:11:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
317 [11/06/08 09:09:12:109]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
318 [11/06/08 09:09:17:062]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
319 [11/06/08 09:09:23:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
320 [11/06/08 09:09:23:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
321 [11/06/08 09:09:23:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
322 [11/06/08 09:09:26:375]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
323 [11/06/08 09:09:27:437]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
324 [11/06/08 09:09:29:875]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
325 [11/06/08 09:09:29:937]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
326 [11/06/08 09:09:33:875]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x15 0xA4', Luminosit: 57.76 Lux
327 [11/06/08 09:09:35:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
328 [11/06/08 09:09:35:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
329 [11/06/08 09:09:35:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
330 [11/06/08 09:09:38:265]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x00', Soire rception ON/OFF: off
331 [11/06/08 09:09:38:812]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
332 [11/06/08 09:09:40:375]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x01', Soire rception ON/OFF: on
333 [11/06/08 09:09:40:453]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir chambre: on
334 [11/06/08 09:09:42:937]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
335 [11/06/08 09:09:43:000]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
336 [11/06/08 09:09:44:937]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
337 [11/06/08 09:09:46:937]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
338 [11/06/08 09:09:47:000]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
339 [11/06/08 09:09:47:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xF6 0x00 0x00', Puissance Hall: 123.00 W
340 [11/06/08 09:09:47:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xC7 0x00 0x00', Puissance Chambre: 1592.00 W
341 [11/06/08 09:09:47:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0xE8 0x00 0x00', Puissance Extrieur: 29.00 W
342 [11/06/08 09:09:49:500]: GroupDataConfirmationWrite: 04/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Soire rception ON/OFF: off
343 [11/06/08 09:09:54:937]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
344 [11/06/08 09:09:59:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
345 [11/06/08 09:09:59:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Chambre: 99.00 W
346 [11/06/08 09:09:59:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
347 [11/06/08 09:10:02:875]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
348 [11/06/08 09:10:03:687]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir chambre: off
349 [11/06/08 09:10:03:750]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
350 [11/06/08 09:10:04:375]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
351 [11/06/08 09:10:04:375]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
352 [11/06/08 09:10:06:062]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
353 [11/06/08 09:10:06:062]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
354 [11/06/08 09:10:09:562]: GroupDataConfirmationWrite: 04/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Soire rception ON/OFF: on
355 [11/06/08 09:10:09:625]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir chambre: on
356 [11/06/08 09:10:11:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
357 [11/06/08 09:10:11:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
358 [11/06/08 09:10:11:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
359 [11/06/08 09:10:23:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
360 [11/06/08 09:10:23:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Chambre: 99.00 W
361 [11/06/08 09:10:23:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
362 [11/06/08 09:10:28:437]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x00', Soire rception ON/OFF: off
363 [11/06/08 09:10:28:500]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
364 [11/06/08 09:10:34:500]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x15 0xDA', Luminosit: 59.92 Lux
365 [11/06/08 09:10:35:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Hall: 99.00 W
366 [11/06/08 09:10:35:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC8 0x00 0x00', Puissance Chambre: 100.00 W
367 [11/06/08 09:10:35:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
368 [11/06/08 09:10:37:375]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
369 [11/06/08 09:10:43:562]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
370 [11/06/08 09:10:44:250]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir chambre: off
371 [11/06/08 09:10:46:687]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
372 [11/06/08 09:10:47:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
373 [11/06/08 09:10:47:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xBA 0x00 0x00', Puissance Chambre: 93.00 W
374 [11/06/08 09:10:47:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
375 [11/06/08 09:10:59:187]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
376 [11/06/08 09:10:59:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
377 [11/06/08 09:10:59:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
378 [11/06/08 09:10:59:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
379 [11/06/08 09:10:59:937]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
380 [11/06/08 09:10:59:937]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
381 [11/06/08 09:11:06:437]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
382 [11/06/08 09:11:06:437]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
383 [11/06/08 09:11:08:812]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
384 [11/06/08 09:11:10:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
385 [11/06/08 09:11:10:140]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
386 [11/06/08 09:11:10:140]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
387 [11/06/08 09:11:14:500]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
388 [11/06/08 09:11:18:937]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
389 [11/06/08 09:11:20:500]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
390 [11/06/08 09:11:20:562]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
391 [11/06/08 09:11:22:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
392 [11/06/08 09:11:22:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
393 [11/06/08 09:11:22:062]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
394 [11/06/08 09:11:28:484]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
395 [11/06/08 09:11:28:484]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
396 [11/06/08 09:11:32:484]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x16 0x27', Luminosit: 63.00 Lux
397 [11/06/08 09:11:33:296]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
398 [11/06/08 09:11:33:984]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
399 [11/06/08 09:11:33:984]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
400 [11/06/08 09:11:34:046]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
401 [11/06/08 09:11:34:109]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
402 [11/06/08 09:11:34:171]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
403 [11/06/08 09:11:34:421]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
404 [11/06/08 09:11:38:421]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
405 [11/06/08 09:11:44:359]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
406 [11/06/08 09:11:45:921]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
407 [11/06/08 09:11:45:921]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
408 [11/06/08 09:11:46:031]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
409 [11/06/08 09:11:57:921]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
410 [11/06/08 09:11:58:046]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
411 [11/06/08 09:11:58:046]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
412 [11/06/08 09:11:58:359]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x04', Temprature chambre: 20.80 C
413 [11/06/08 09:12:02:796]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x16 0x7C', Luminosit: 66.40 Lux
414 [11/06/08 09:12:06:859]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
415 [11/06/08 09:12:06:859]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
416 [11/06/08 09:12:09:859]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
417 [11/06/08 09:12:09:859]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
418 [11/06/08 09:12:09:953]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
419 [11/06/08 09:12:21:796]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
420 [11/06/08 09:12:21:796]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
421 [11/06/08 09:12:21:859]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
422 [11/06/08 09:12:33:796]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
423 [11/06/08 09:12:33:796]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
424 [11/06/08 09:12:33:921]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
425 [11/06/08 09:12:36:171]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
426 [11/06/08 09:12:45:734]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
427 [11/06/08 09:12:45:734]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
428 [11/06/08 09:12:45:796]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
429 [11/06/08 09:12:47:671]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
430 [11/06/08 09:12:57:671]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
431 [11/06/08 09:12:57:671]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
432 [11/06/08 09:12:57:734]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
433 [11/06/08 09:13:03:484]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x16 0xB5', Luminosit: 68.68 Lux
434 [11/06/08 09:13:03:984]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
435 [11/06/08 09:13:07:234]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
436 [11/06/08 09:13:07:234]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
437 [11/06/08 09:13:09:609]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
438 [11/06/08 09:13:09:671]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
439 [11/06/08 09:13:09:671]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
440 [11/06/08 09:13:21:609]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
441 [11/06/08 09:13:21:609]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
442 [11/06/08 09:13:21:609]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
443 [11/06/08 09:13:23:859]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
444 [11/06/08 09:13:25:921]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
445 [11/06/08 09:13:25:921]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
446 [11/06/08 09:13:33:421]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
447 [11/06/08 09:13:33:546]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
448 [11/06/08 09:13:33:546]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
449 [11/06/08 09:13:33:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
450 [11/06/08 09:13:37:859]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
451 [11/06/08 09:13:45:484]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
452 [11/06/08 09:13:45:484]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
453 [11/06/08 09:13:45:593]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
454 [11/06/08 09:13:57:421]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
455 [11/06/08 09:13:57:484]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
456 [11/06/08 09:13:57:484]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
457 [11/06/08 09:14:04:046]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x16 0xE5', Luminosit: 70.60 Lux
458 [11/06/08 09:14:05:734]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
459 [11/06/08 09:14:07:671]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
460 [11/06/08 09:14:07:671]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
461 [11/06/08 09:14:09:421]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
462 [11/06/08 09:14:09:421]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
463 [11/06/08 09:14:09:421]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
464 [11/06/08 09:14:21:359]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
465 [11/06/08 09:14:21:359]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
466 [11/06/08 09:14:21:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
467 [11/06/08 09:14:33:296]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
468 [11/06/08 09:14:33:296]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
469 [11/06/08 09:14:33:359]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
470 [11/06/08 09:14:37:546]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
471 [11/06/08 09:14:37:609]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
472 [11/06/08 09:14:39:546]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFD', Temprature chambre: 20.24 C
473 [11/06/08 09:14:45:234]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x00 0x00 0x00', Puissance Hall: 128.00 W
474 [11/06/08 09:14:45:296]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xEC 0x20 0x00', Puissance Chambre: 1889.00 W
475 [11/06/08 09:14:45:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x08 0x00 0x00', Puissance Extrieur: 34.00 W
476 [11/06/08 09:14:45:546]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
477 [11/06/08 09:14:45:609]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
478 [11/06/08 09:14:49:484]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
479 [11/06/08 09:14:53:484]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
480 [11/06/08 09:14:56:671]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x01', Soire rception ON/OFF: on
481 [11/06/08 09:14:56:734]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir chambre: on
482 [11/06/08 09:14:57:234]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
483 [11/06/08 09:14:57:234]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
484 [11/06/08 09:14:57:296]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
485 [11/06/08 09:14:59:484]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
486 [11/06/08 09:15:01:046]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x00', Soire rception ON/OFF: off
487 [11/06/08 09:15:01:046]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
488 [11/06/08 09:15:03:421]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
489 [11/06/08 09:15:04:796]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x33', Luminosit: 73.72 Lux
490 [11/06/08 09:15:08:046]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
491 [11/06/08 09:15:08:046]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
492 [11/06/08 09:15:09:109]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Hall: 99.00 W
493 [11/06/08 09:15:09:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC8 0x00 0x00', Puissance Chambre: 100.00 W
494 [11/06/08 09:15:09:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
495 [11/06/08 09:15:09:859]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
496 [11/06/08 09:15:11:171]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
497 [11/06/08 09:15:15:171]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir chambre: off
498 [11/06/08 09:15:15:546]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
499 [11/06/08 09:15:21:109]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
500 [11/06/08 09:15:21:171]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
501 [11/06/08 09:15:21:171]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
502 [11/06/08 09:15:24:546]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
503 [11/06/08 09:15:25:734]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
504 [11/06/08 09:15:33:046]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
505 [11/06/08 09:15:33:109]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
506 [11/06/08 09:15:33:109]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
507 [11/06/08 09:15:40:734]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
508 [11/06/08 09:15:42:234]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
509 [11/06/08 09:15:42:296]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
510 [11/06/08 09:15:44:984]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0x40 0x00 0x00', Puissance Hall: 48.00 W
511 [11/06/08 09:15:45:046]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
512 [11/06/08 09:15:45:046]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
513 [11/06/08 09:15:51:796]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
514 [11/06/08 09:15:56:984]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
515 [11/06/08 09:15:57:046]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
516 [11/06/08 09:15:57:046]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
517 [11/06/08 09:15:57:171]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x97', Luminosit: 77.72 Lux
518 [11/06/08 09:16:01:171]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
519 [11/06/08 09:16:01:609]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
520 [11/06/08 09:16:03:046]: GroupDataConfirmationRead: 06/0002, RoutingCnt=6, PriorityLow, No Error
521 [11/06/08 09:16:08:359]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
522 [11/06/08 09:16:08:421]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
523 [11/06/08 09:16:08:921]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
524 [11/06/08 09:16:08:984]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
525 [11/06/08 09:16:08:984]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
526 [11/06/08 09:16:09:046]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
527 [11/06/08 09:16:11:359]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
528 [11/06/08 09:16:15:796]: GroupDataConfirmationRead: 06/0002, RoutingCnt=6, PriorityLow, No Error
529 [11/06/08 09:16:17:109]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
530 [11/06/08 09:16:17:109]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
531 [11/06/08 09:16:19:109]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
532 [11/06/08 09:16:19:109]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
533 [11/06/08 09:16:19:546]: GroupDataConfirmationRead: 06/0002, RoutingCnt=6, PriorityLow, No Error
534 [11/06/08 09:16:20:296]: GroupDataConfirmationRead: 06/0002, RoutingCnt=6, PriorityLow, No Error
535 [11/06/08 09:16:20:484]: GroupDataConfirmationRead: 06/0002, RoutingCnt=6, PriorityLow, No Error
536 [11/06/08 09:16:20:921]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x00 0x00 0x00', Puissance Hall: 128.00 W
537 [11/06/08 09:16:20:921]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xE8 0xA0 0x00', Puissance Chambre: 1861.00 W
538 [11/06/08 09:16:20:984]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x08 0x00 0x00', Puissance Extrieur: 34.00 W
539 [11/06/08 09:16:25:546]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
540 [11/06/08 09:16:25:984]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
541 [11/06/08 09:16:26:046]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
542 [11/06/08 09:16:32:921]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
543 [11/06/08 09:16:32:921]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
544 [11/06/08 09:16:32:984]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
545 [11/06/08 09:16:35:859]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
546 [11/06/08 09:16:36:484]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0xFA', Luminosit: 81.68 Lux
547 [11/06/08 09:16:36:546]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
548 [11/06/08 09:16:37:046]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
549 [11/06/08 09:16:42:546]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
550 [11/06/08 09:16:44:921]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
551 [11/06/08 09:16:44:921]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
552 [11/06/08 09:16:44:921]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
553 [11/06/08 09:16:51:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
554 [11/06/08 09:16:53:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
555 [11/06/08 09:16:55:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
556 [11/06/08 09:16:56:859]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
557 [11/06/08 09:16:56:921]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
558 [11/06/08 09:16:56:921]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
559 [11/06/08 09:16:57:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
560 [11/06/08 09:16:59:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
561 [11/06/08 09:17:01:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
562 [11/06/08 09:17:03:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
563 [11/06/08 09:17:05:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
564 [11/06/08 09:17:07:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
565 [11/06/08 09:17:08:859]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
566 [11/06/08 09:17:08:859]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
567 [11/06/08 09:17:08:953]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
568 [11/06/08 09:17:08:968]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
569 [11/06/08 09:17:08:968]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
570 [11/06/08 09:17:09:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
571 [11/06/08 09:17:10:859]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
572 [11/06/08 09:17:11:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
573 [11/06/08 09:17:13:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
574 [11/06/08 09:17:15:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
575 [11/06/08 09:17:17:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
576 [11/06/08 09:17:19:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
577 [11/06/08 09:17:20:859]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
578 [11/06/08 09:17:20:859]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
579 [11/06/08 09:17:20:921]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
580 [11/06/08 09:17:21:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
581 [11/06/08 09:17:21:609]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
582 [11/06/08 09:17:23:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
583 [11/06/08 09:17:25:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
584 [11/06/08 09:17:27:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
585 [11/06/08 09:17:29:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
586 [11/06/08 09:17:30:359]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
587 [11/06/08 09:17:31:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
588 [11/06/08 09:17:32:796]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
589 [11/06/08 09:17:32:859]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
590 [11/06/08 09:17:32:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
591 [11/06/08 09:17:33:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
592 [11/06/08 09:17:35:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
593 [11/06/08 09:17:37:046]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x0A', Luminosit: 82.72 Lux
594 [11/06/08 09:17:37:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
595 [11/06/08 09:17:39:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
596 [11/06/08 09:17:40:859]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
597 [11/06/08 09:17:41:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
598 [11/06/08 09:17:43:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
599 [11/06/08 09:17:44:671]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
600 [11/06/08 09:17:44:796]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC0 0x00 0x00', Puissance Hall: 96.00 W
601 [11/06/08 09:17:44:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
602 [11/06/08 09:17:44:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
603 [11/06/08 09:17:45:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
604 [11/06/08 09:17:47:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
605 [11/06/08 09:17:49:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
606 [11/06/08 09:17:51:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
607 [11/06/08 09:17:51:359]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
608 [11/06/08 09:17:53:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
609 [11/06/08 09:17:54:609]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
610 [11/06/08 09:17:54:671]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
611 [11/06/08 09:17:55:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
612 [11/06/08 09:17:56:796]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
613 [11/06/08 09:17:56:796]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
614 [11/06/08 09:17:56:859]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
615 [11/06/08 09:17:57:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
616 [11/06/08 09:17:59:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
617 [11/06/08 09:18:00:609]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
618 [11/06/08 09:18:00:671]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
619 [11/06/08 09:18:01:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
620 [11/06/08 09:18:01:796]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
621 [11/06/08 09:18:03:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
622 [11/06/08 09:18:05:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
623 [11/06/08 09:18:07:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
624 [11/06/08 09:18:08:546]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
625 [11/06/08 09:18:08:796]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
626 [11/06/08 09:18:08:796]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
627 [11/06/08 09:18:08:859]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
628 [11/06/08 09:18:09:109]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
629 [11/06/08 09:18:09:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
630 [11/06/08 09:18:09:171]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
631 [11/06/08 09:18:11:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
632 [11/06/08 09:18:12:296]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
633 [11/06/08 09:18:13:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
634 [11/06/08 09:18:15:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
635 [11/06/08 09:18:17:046]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
636 [11/06/08 09:18:17:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
637 [11/06/08 09:18:18:546]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
638 [11/06/08 09:18:18:546]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
639 [11/06/08 09:18:19:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
640 [11/06/08 09:18:20:734]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
641 [11/06/08 09:18:20:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
642 [11/06/08 09:18:20:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
643 [11/06/08 09:18:21:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
644 [11/06/08 09:18:23:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
645 [11/06/08 09:18:25:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
646 [11/06/08 09:18:26:984]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
647 [11/06/08 09:18:27:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
648 [11/06/08 09:18:29:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
649 [11/06/08 09:18:30:484]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x4F', Luminosit: 74.84 Lux
650 [11/06/08 09:18:31:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
651 [11/06/08 09:18:32:734]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
652 [11/06/08 09:18:32:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
653 [11/06/08 09:18:32:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
654 [11/06/08 09:18:33:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
655 [11/06/08 09:18:33:921]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x16', Luminosit: 83.68 Lux
656 [11/06/08 09:18:35:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
657 [11/06/08 09:18:37:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
658 [11/06/08 09:18:37:484]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
659 [11/06/08 09:18:39:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
660 [11/06/08 09:18:40:234]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
661 [11/06/08 09:18:41:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
662 [11/06/08 09:18:43:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
663 [11/06/08 09:18:44:734]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
664 [11/06/08 09:18:44:734]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
665 [11/06/08 09:18:44:796]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
666 [11/06/08 09:18:45:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
667 [11/06/08 09:18:47:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
668 [11/06/08 09:18:49:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
669 [11/06/08 09:18:51:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
670 [11/06/08 09:18:52:734]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
671 [11/06/08 09:18:53:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
672 [11/06/08 09:18:55:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
673 [11/06/08 09:18:56:734]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
674 [11/06/08 09:18:56:734]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
675 [11/06/08 09:18:56:734]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
676 [11/06/08 09:18:57:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
677 [11/06/08 09:18:59:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
678 [11/06/08 09:19:01:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
679 [11/06/08 09:19:02:609]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
680 [11/06/08 09:19:03:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
681 [11/06/08 09:19:04:359]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
682 [11/06/08 09:19:05:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
683 [11/06/08 09:19:07:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
684 [11/06/08 09:19:08:671]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
685 [11/06/08 09:19:08:734]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
686 [11/06/08 09:19:08:734]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
687 [11/06/08 09:19:09:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
688 [11/06/08 09:19:09:671]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
689 [11/06/08 09:19:09:671]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
690 [11/06/08 09:19:11:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
691 [11/06/08 09:19:13:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
692 [11/06/08 09:19:14:859]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
693 [11/06/08 09:19:15:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
694 [11/06/08 09:19:16:234]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
695 [11/06/08 09:19:17:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
696 [11/06/08 09:19:19:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
697 [11/06/08 09:19:20:671]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
698 [11/06/08 09:19:20:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
699 [11/06/08 09:19:20:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
700 [11/06/08 09:19:21:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
701 [11/06/08 09:19:23:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
702 [11/06/08 09:19:23:609]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
703 [11/06/08 09:19:25:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
704 [11/06/08 09:19:26:734]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
705 [11/06/08 09:19:27:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
706 [11/06/08 09:19:29:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
707 [11/06/08 09:19:30:296]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
708 [11/06/08 09:19:31:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
709 [11/06/08 09:19:31:609]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
710 [11/06/08 09:19:32:171]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
711 [11/06/08 09:19:32:234]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
712 [11/06/08 09:19:32:671]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
713 [11/06/08 09:19:32:671]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
714 [11/06/08 09:19:32:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
715 [11/06/08 09:19:33:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
716 [11/06/08 09:19:34:484]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x12', Luminosit: 83.36 Lux
717 [11/06/08 09:19:35:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
718 [11/06/08 09:19:37:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
719 [11/06/08 09:19:38:171]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
720 [11/06/08 09:19:38:171]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
721 [11/06/08 09:19:39:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
722 [11/06/08 09:19:40:359]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
723 [11/06/08 09:19:41:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
724 [11/06/08 09:19:43:109]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
725 [11/06/08 09:19:43:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
726 [11/06/08 09:19:44:671]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
727 [11/06/08 09:19:44:671]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
728 [11/06/08 09:19:44:671]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
729 [11/06/08 09:19:45:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
730 [11/06/08 09:19:47:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
731 [11/06/08 09:19:49:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
732 [11/06/08 09:19:51:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
733 [11/06/08 09:19:53:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
734 [11/06/08 09:19:54:046]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
735 [11/06/08 09:19:55:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
736 [11/06/08 09:19:56:609]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
737 [11/06/08 09:19:56:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
738 [11/06/08 09:19:56:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
739 [11/06/08 09:19:57:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
740 [11/06/08 09:19:59:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
741 [11/06/08 09:20:01:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
742 [11/06/08 09:20:02:046]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
743 [11/06/08 09:20:03:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
744 [11/06/08 09:20:05:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
745 [11/06/08 09:20:07:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
746 [11/06/08 09:20:07:359]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
747 [11/06/08 09:20:08:609]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
748 [11/06/08 09:20:08:609]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
749 [11/06/08 09:20:08:718]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
750 [11/06/08 09:20:09:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
751 [11/06/08 09:20:10:046]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
752 [11/06/08 09:20:10:046]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
753 [11/06/08 09:20:11:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
754 [11/06/08 09:20:13:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
755 [11/06/08 09:20:15:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
756 [11/06/08 09:20:16:046]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
757 [11/06/08 09:20:17:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
758 [11/06/08 09:20:19:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
759 [11/06/08 09:20:20:609]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
760 [11/06/08 09:20:20:609]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
761 [11/06/08 09:20:20:671]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
762 [11/06/08 09:20:21:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
763 [11/06/08 09:20:23:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
764 [11/06/08 09:20:25:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
765 [11/06/08 09:20:26:546]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
766 [11/06/08 09:20:27:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
767 [11/06/08 09:20:29:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
768 [11/06/08 09:20:31:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
769 [11/06/08 09:20:32:546]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
770 [11/06/08 09:20:32:609]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
771 [11/06/08 09:20:32:609]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
772 [11/06/08 09:20:33:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
773 [11/06/08 09:20:35:171]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x18', Luminosit: 83.84 Lux
774 [11/06/08 09:20:35:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
775 [11/06/08 09:20:36:984]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
776 [11/06/08 09:20:37:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
777 [11/06/08 09:20:39:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
778 [11/06/08 09:20:41:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
779 [11/06/08 09:20:43:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
780 [11/06/08 09:20:44:546]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
781 [11/06/08 09:20:44:609]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
782 [11/06/08 09:20:44:609]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
783 [11/06/08 09:20:45:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
784 [11/06/08 09:20:47:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
785 [11/06/08 09:20:47:484]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
786 [11/06/08 09:20:49:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
787 [11/06/08 09:20:51:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
788 [11/06/08 09:20:53:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
789 [11/06/08 09:20:55:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
790 [11/06/08 09:20:55:734]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
791 [11/06/08 09:20:56:546]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
792 [11/06/08 09:20:56:546]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
793 [11/06/08 09:20:56:609]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
794 [11/06/08 09:20:57:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
795 [11/06/08 09:20:57:984]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
796 [11/06/08 09:20:58:109]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
797 [11/06/08 09:20:59:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
798 [11/06/08 09:21:00:984]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
799 [11/06/08 09:21:01:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
800 [11/06/08 09:21:03:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
801 [11/06/08 09:21:05:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
802 [11/06/08 09:21:07:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
803 [11/06/08 09:21:08:546]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
804 [11/06/08 09:21:08:546]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
805 [11/06/08 09:21:08:609]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
806 [11/06/08 09:21:09:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
807 [11/06/08 09:21:09:671]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
808 [11/06/08 09:21:09:734]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
809 [11/06/08 09:21:10:359]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
810 [11/06/08 09:21:10:359]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
811 [11/06/08 09:21:10:546]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
812 [11/06/08 09:21:11:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
813 [11/06/08 09:21:11:671]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
814 [11/06/08 09:21:11:750]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
815 [11/06/08 09:21:13:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
816 [11/06/08 09:21:14:859]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
817 [11/06/08 09:21:15:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
818 [11/06/08 09:21:17:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
819 [11/06/08 09:21:19:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
820 [11/06/08 09:21:20:546]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
821 [11/06/08 09:21:20:546]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
822 [11/06/08 09:21:20:546]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
823 [11/06/08 09:21:20:703]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
824 [11/06/08 09:21:21:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
825 [11/06/08 09:21:23:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
826 [11/06/08 09:21:25:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
827 [11/06/08 09:21:27:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
828 [11/06/08 09:21:29:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
829 [11/06/08 09:21:29:421]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
830 [11/06/08 09:21:31:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
831 [11/06/08 09:21:32:484]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
832 [11/06/08 09:21:32:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
833 [11/06/08 09:21:32:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
834 [11/06/08 09:21:33:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
835 [11/06/08 09:21:35:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
836 [11/06/08 09:21:35:796]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x39', Luminosit: 86.48 Lux
837 [11/06/08 09:21:37:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
838 [11/06/08 09:21:39:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
839 [11/06/08 09:21:41:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
840 [11/06/08 09:21:43:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
841 [11/06/08 09:21:44:484]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
842 [11/06/08 09:21:44:484]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
843 [11/06/08 09:21:44:546]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
844 [11/06/08 09:21:45:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
845 [11/06/08 09:21:47:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
846 [11/06/08 09:21:49:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
847 [11/06/08 09:21:51:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
848 [11/06/08 09:21:53:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
849 [11/06/08 09:21:55:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
850 [11/06/08 09:21:56:484]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
851 [11/06/08 09:21:56:484]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
852 [11/06/08 09:21:56:546]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
853 [11/06/08 09:21:57:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
854 [11/06/08 09:21:59:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
855 [11/06/08 09:22:01:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
856 [11/06/08 09:22:03:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
857 [11/06/08 09:22:05:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
858 [11/06/08 09:22:07:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
859 [11/06/08 09:22:08:421]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
860 [11/06/08 09:22:08:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
861 [11/06/08 09:22:08:515]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
862 [11/06/08 09:22:09:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
863 [11/06/08 09:22:10:859]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
864 [11/06/08 09:22:10:859]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
865 [11/06/08 09:22:11:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
866 [11/06/08 09:22:11:421]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
867 [11/06/08 09:22:13:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
868 [11/06/08 09:22:15:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
869 [11/06/08 09:22:17:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
870 [11/06/08 09:22:19:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
871 [11/06/08 09:22:20:421]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
872 [11/06/08 09:22:20:484]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
873 [11/06/08 09:22:20:484]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
874 [11/06/08 09:22:21:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
875 [11/06/08 09:22:23:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
876 [11/06/08 09:22:25:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
877 [11/06/08 09:22:27:171]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
878 [11/06/08 09:22:29:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
879 [11/06/08 09:22:31:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
880 [11/06/08 09:22:32:390]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
881 [11/06/08 09:22:32:453]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
882 [11/06/08 09:22:32:453]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
883 [11/06/08 09:22:33:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
884 [11/06/08 09:22:35:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
885 [11/06/08 09:22:36:453]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x46', Luminosit: 87.52 Lux
886 [11/06/08 09:22:37:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
887 [11/06/08 09:22:39:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
888 [11/06/08 09:22:39:265]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
889 [11/06/08 09:22:41:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
890 [11/06/08 09:22:43:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
891 [11/06/08 09:22:44:390]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
892 [11/06/08 09:22:44:453]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
893 [11/06/08 09:22:44:453]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
894 [11/06/08 09:22:45:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
895 [11/06/08 09:22:47:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
896 [11/06/08 09:22:47:203]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
897 [11/06/08 09:22:47:328]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
898 [11/06/08 09:22:49:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
899 [11/06/08 09:22:51:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
900 [11/06/08 09:22:51:578]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
901 [11/06/08 09:22:53:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
902 [11/06/08 09:22:53:203]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
903 [11/06/08 09:22:53:265]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
904 [11/06/08 09:22:55:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
905 [11/06/08 09:22:56:390]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xFA 0x00 0x00', Puissance Hall: 125.00 W
906 [11/06/08 09:22:56:390]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xCC 0xE0 0x00', Puissance Chambre: 1639.00 W
907 [11/06/08 09:22:56:468]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0xF0 0x00 0x00', Puissance Extrieur: 30.00 W
908 [11/06/08 09:22:57:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
909 [11/06/08 09:22:59:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
910 [11/06/08 09:23:01:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
911 [11/06/08 09:23:03:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
912 [11/06/08 09:23:03:140]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
913 [11/06/08 09:23:05:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
914 [11/06/08 09:23:07:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
915 [11/06/08 09:23:08:390]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
916 [11/06/08 09:23:08:390]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
917 [11/06/08 09:23:08:390]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
918 [11/06/08 09:23:09:140]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
919 [11/06/08 09:23:09:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
920 [11/06/08 09:23:11:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
921 [11/06/08 09:23:11:203]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
922 [11/06/08 09:23:11:265]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
923 [11/06/08 09:23:13:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
924 [11/06/08 09:23:15:140]: GroupDataConfirmationWrite: 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir hall: off
925 [11/06/08 09:23:20:328]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
926 [11/06/08 09:23:20:390]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
927 [11/06/08 09:23:20:390]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
928 [11/06/08 09:23:23:062]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
929 [11/06/08 09:23:30:062]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
930 [11/06/08 09:23:32:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
931 [11/06/08 09:23:32:390]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
932 [11/06/08 09:23:32:390]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
933 [11/06/08 09:23:37:187]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x3B', Luminosit: 86.64 Lux
934 [11/06/08 09:23:44:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
935 [11/06/08 09:23:44:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
936 [11/06/08 09:23:44:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
937 [11/06/08 09:23:50:937]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
938 [11/06/08 09:23:56:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
939 [11/06/08 09:23:56:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
940 [11/06/08 09:23:56:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
941 [11/06/08 09:24:08:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
942 [11/06/08 09:24:08:328]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
943 [11/06/08 09:24:08:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
944 [11/06/08 09:24:11:687]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
945 [11/06/08 09:24:11:687]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
946 [11/06/08 09:24:18:812]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
947 [11/06/08 09:24:20:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
948 [11/06/08 09:24:20:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
949 [11/06/08 09:24:20:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
950 [11/06/08 09:24:26:750]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
951 [11/06/08 09:24:26:812]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
952 [11/06/08 09:24:30:750]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
953 [11/06/08 09:24:30:812]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
954 [11/06/08 09:24:33:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x41 0xC8 0x00 0x00', Puissance Hall: 25.00 W
955 [11/06/08 09:24:33:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xC0 0xA0 0x00', Puissance Chambre: 1541.00 W
956 [11/06/08 09:24:33:125]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0xD8 0x00 0x00', Puissance Extrieur: 27.00 W
957 [11/06/08 09:24:37:750]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x44', Luminosit: 87.36 Lux
958 [11/06/08 09:24:42:687]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
959 [11/06/08 09:24:44:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
960 [11/06/08 09:24:44:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
961 [11/06/08 09:24:44:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
962 [11/06/08 09:24:56:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
963 [11/06/08 09:24:57:015]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
964 [11/06/08 09:24:57:015]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
965 [11/06/08 09:25:08:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
966 [11/06/08 09:25:08:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
967 [11/06/08 09:25:08:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
968 [11/06/08 09:25:12:000]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
969 [11/06/08 09:25:12:062]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
970 [11/06/08 09:25:20:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
971 [11/06/08 09:25:20:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
972 [11/06/08 09:25:20:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
973 [11/06/08 09:25:32:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
974 [11/06/08 09:25:32:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
975 [11/06/08 09:25:32:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
976 [11/06/08 09:25:38:500]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x4D', Luminosit: 88.08 Lux
977 [11/06/08 09:25:44:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
978 [11/06/08 09:25:44:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
979 [11/06/08 09:25:44:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
980 [11/06/08 09:25:50:375]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
981 [11/06/08 09:25:56:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
982 [11/06/08 09:25:56:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
983 [11/06/08 09:25:56:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
984 [11/06/08 09:26:04:312]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
985 [11/06/08 09:26:04:312]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
986 [11/06/08 09:26:08:250]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
987 [11/06/08 09:26:08:312]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
988 [11/06/08 09:26:08:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x41 0xF0 0x00 0x00', Puissance Hall: 30.00 W
989 [11/06/08 09:26:08:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xEF 0x00 0x00', Puissance Chambre: 1912.00 W
990 [11/06/08 09:26:08:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x08 0x00 0x00', Puissance Extrieur: 34.00 W
991 [11/06/08 09:26:12:375]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
992 [11/06/08 09:26:12:375]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
993 [11/06/08 09:26:12:937]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
994 [11/06/08 09:26:20:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
995 [11/06/08 09:26:20:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
996 [11/06/08 09:26:20:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
997 [11/06/08 09:26:28:187]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
998 [11/06/08 09:26:32:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
999 [11/06/08 09:26:32:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1000 [11/06/08 09:26:32:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1001 [11/06/08 09:26:39:062]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x4E', Luminosit: 88.16 Lux
1002 [11/06/08 09:26:44:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1003 [11/06/08 09:26:44:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1004 [11/06/08 09:26:44:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1005 [11/06/08 09:26:56:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1006 [11/06/08 09:26:56:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1007 [11/06/08 09:26:56:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1008 [11/06/08 09:27:08:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1009 [11/06/08 09:27:08:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1010 [11/06/08 09:27:08:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1011 [11/06/08 09:27:10:000]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1012 [11/06/08 09:27:12:812]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1013 [11/06/08 09:27:12:875]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1014 [11/06/08 09:27:20:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1015 [11/06/08 09:27:20:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1016 [11/06/08 09:27:20:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1017 [11/06/08 09:27:32:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1018 [11/06/08 09:27:32:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1019 [11/06/08 09:27:32:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1020 [11/06/08 09:27:39:750]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x49', Luminosit: 87.76 Lux
1021 [11/06/08 09:27:39:875]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1022 [11/06/08 09:27:39:937]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1023 [11/06/08 09:27:43:812]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
1024 [11/06/08 09:27:44:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x41 0xF0 0x00 0x00', Puissance Hall: 30.00 W
1025 [11/06/08 09:27:44:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xED 0xE0 0x00', Puissance Chambre: 1903.00 W
1026 [11/06/08 09:27:44:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x08 0x00 0x00', Puissance Extrieur: 34.00 W
1027 [11/06/08 09:27:45:812]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1028 [11/06/08 09:27:45:875]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1029 [11/06/08 09:27:53:812]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1030 [11/06/08 09:27:56:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1031 [11/06/08 09:27:56:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1032 [11/06/08 09:27:56:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1033 [11/06/08 09:27:57:750]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1034 [11/06/08 09:28:03:750]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
1035 [11/06/08 09:28:08:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Hall: 2.00 W
1036 [11/06/08 09:28:08:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1037 [11/06/08 09:28:08:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1038 [11/06/08 09:28:13:250]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1039 [11/06/08 09:28:13:250]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1040 [11/06/08 09:28:20:156]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1041 [11/06/08 09:28:20:156]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1042 [11/06/08 09:28:20:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1043 [11/06/08 09:28:32:078]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1044 [11/06/08 09:28:32:078]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1045 [11/06/08 09:28:32:078]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1046 [11/06/08 09:28:40:312]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x32', Luminosit: 85.92 Lux
1047 [11/06/08 09:28:44:140]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1048 [11/06/08 09:28:44:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1049 [11/06/08 09:28:44:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1050 [11/06/08 09:28:55:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1051 [11/06/08 09:28:56:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1052 [11/06/08 09:28:56:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1053 [11/06/08 09:29:07:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1054 [11/06/08 09:29:07:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1055 [11/06/08 09:29:07:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1056 [11/06/08 09:29:09:437]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1057 [11/06/08 09:29:13:625]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1058 [11/06/08 09:29:13:625]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1059 [11/06/08 09:29:19:437]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1060 [11/06/08 09:29:19:453]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1061 [11/06/08 09:29:19:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1062 [11/06/08 09:29:19:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1063 [11/06/08 09:29:19:984]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1064 [11/06/08 09:29:21:500]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1065 [11/06/08 09:29:21:625]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1066 [11/06/08 09:29:31:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1067 [11/06/08 09:29:31:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1068 [11/06/08 09:29:31:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1069 [11/06/08 09:29:34:250]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
1070 [11/06/08 09:29:41:062]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x2E', Luminosit: 85.60 Lux
1071 [11/06/08 09:29:43:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1072 [11/06/08 09:29:43:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1073 [11/06/08 09:29:43:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1074 [11/06/08 09:29:55:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1075 [11/06/08 09:29:55:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1076 [11/06/08 09:29:55:906]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1077 [11/06/08 09:30:07:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1078 [11/06/08 09:30:07:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1079 [11/06/08 09:30:07:906]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1080 [11/06/08 09:30:14:000]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1081 [11/06/08 09:30:14:062]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1082 [11/06/08 09:30:19:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1083 [11/06/08 09:30:19:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1084 [11/06/08 09:30:19:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1085 [11/06/08 09:30:21:062]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1086 [11/06/08 09:30:31:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1087 [11/06/08 09:30:31:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1088 [11/06/08 09:30:31:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1089 [11/06/08 09:30:41:750]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x4F', Luminosit: 88.24 Lux
1090 [11/06/08 09:30:43:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1091 [11/06/08 09:30:43:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1092 [11/06/08 09:30:43:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1093 [11/06/08 09:30:44:937]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
1094 [11/06/08 09:30:55:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1095 [11/06/08 09:30:55:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1096 [11/06/08 09:30:55:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1097 [11/06/08 09:30:56:937]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1098 [11/06/08 09:30:56:937]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1099 [11/06/08 09:31:04:875]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1100 [11/06/08 09:31:04:937]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1101 [11/06/08 09:31:07:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x41 0x98 0x00 0x00', Puissance Hall: 19.00 W
1102 [11/06/08 09:31:07:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0x95 0x40 0x00', Puissance Chambre: 1194.00 W
1103 [11/06/08 09:31:07:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0xA8 0x00 0x00', Puissance Extrieur: 21.00 W
1104 [11/06/08 09:31:12:812]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1105 [11/06/08 09:31:14:312]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1106 [11/06/08 09:31:14:375]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1107 [11/06/08 09:31:18:812]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1108 [11/06/08 09:31:19:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1109 [11/06/08 09:31:19:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1110 [11/06/08 09:31:19:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1111 [11/06/08 09:31:22:812]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
1112 [11/06/08 09:31:31:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1113 [11/06/08 09:31:31:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1114 [11/06/08 09:31:31:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1115 [11/06/08 09:31:32:750]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x04', Temprature chambre: 20.80 C
1116 [11/06/08 09:31:42:375]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x59', Luminosit: 89.04 Lux
1117 [11/06/08 09:31:43:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1118 [11/06/08 09:31:43:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1119 [11/06/08 09:31:43:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1120 [11/06/08 09:31:55:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1121 [11/06/08 09:31:55:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1122 [11/06/08 09:31:55:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1123 [11/06/08 09:32:07:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1124 [11/06/08 09:32:07:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1125 [11/06/08 09:32:07:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1126 [11/06/08 09:32:14:812]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1127 [11/06/08 09:32:14:812]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1128 [11/06/08 09:32:19:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1129 [11/06/08 09:32:19:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1130 [11/06/08 09:32:19:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1131 [11/06/08 09:32:20:500]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
1132 [11/06/08 09:32:31:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1133 [11/06/08 09:32:31:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1134 [11/06/08 09:32:31:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1135 [11/06/08 09:32:43:000]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x58', Luminosit: 88.96 Lux
1136 [11/06/08 09:32:43:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1137 [11/06/08 09:32:43:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1138 [11/06/08 09:32:43:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1139 [11/06/08 09:32:54:375]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1140 [11/06/08 09:32:55:562]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
1141 [11/06/08 09:32:55:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
1142 [11/06/08 09:32:55:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1143 [11/06/08 09:32:55:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1144 [11/06/08 09:32:57:750]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1145 [11/06/08 09:32:57:812]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1146 [11/06/08 09:33:02:312]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1147 [11/06/08 09:33:02:312]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
1148 [11/06/08 09:33:07:187]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1149 [11/06/08 09:33:07:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
1150 [11/06/08 09:33:07:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1151 [11/06/08 09:33:07:578]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1152 [11/06/08 09:33:15:187]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1153 [11/06/08 09:33:15:187]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1154 [11/06/08 09:33:17:687]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1155 [11/06/08 09:33:19:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
1156 [11/06/08 09:33:19:578]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
1157 [11/06/08 09:33:19:578]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1158 [11/06/08 09:33:19:937]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1159 [11/06/08 09:33:31:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
1160 [11/06/08 09:33:31:515]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1161 [11/06/08 09:33:31:593]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1162 [11/06/08 09:33:32:187]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1163 [11/06/08 09:33:35:937]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1164 [11/06/08 09:33:36:312]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1165 [11/06/08 09:33:36:375]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1166 [11/06/08 09:33:43:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1167 [11/06/08 09:33:43:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
1168 [11/06/08 09:33:43:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1169 [11/06/08 09:33:43:625]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x24', Luminosit: 84.80 Lux
1170 [11/06/08 09:33:44:937]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1171 [11/06/08 09:33:48:250]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1172 [11/06/08 09:33:55:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1173 [11/06/08 09:33:55:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1174 [11/06/08 09:33:55:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1175 [11/06/08 09:34:00:062]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
1176 [11/06/08 09:34:03:625]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1177 [11/06/08 09:34:04:000]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1178 [11/06/08 09:34:04:062]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1179 [11/06/08 09:34:07:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0x9C 0x00 0x00', Puissance Hall: 78.00 W
1180 [11/06/08 09:34:07:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
1181 [11/06/08 09:34:07:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1182 [11/06/08 09:34:13:937]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1183 [11/06/08 09:34:14:000]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1184 [11/06/08 09:34:14:312]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1185 [11/06/08 09:34:15:562]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1186 [11/06/08 09:34:15:625]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1187 [11/06/08 09:34:16:000]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1188 [11/06/08 09:34:19:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x00 0x00 0x00', Puissance Hall: 128.00 W
1189 [11/06/08 09:34:19:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xEE 0xA0 0x00', Puissance Chambre: 1909.00 W
1190 [11/06/08 09:34:19:546]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x0C 0x00 0x00', Puissance Extrieur: 35.00 W
1191 [11/06/08 09:34:19:937]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1192 [11/06/08 09:34:20:000]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1193 [11/06/08 09:34:31:375]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1194 [11/06/08 09:34:31:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1195 [11/06/08 09:34:31:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1196 [11/06/08 09:34:31:531]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1197 [11/06/08 09:34:31:687]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1198 [11/06/08 09:34:31:750]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1199 [11/06/08 09:34:33:875]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1200 [11/06/08 09:34:37:875]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1201 [11/06/08 09:34:41:562]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1202 [11/06/08 09:34:43:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1203 [11/06/08 09:34:43:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
1204 [11/06/08 09:34:43:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1205 [11/06/08 09:34:43:687]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1206 [11/06/08 09:34:44:312]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x19', Luminosit: 83.92 Lux
1207 [11/06/08 09:34:55:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1208 [11/06/08 09:34:55:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1209 [11/06/08 09:34:55:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1210 [11/06/08 09:34:59:125]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1211 [11/06/08 09:34:59:500]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1212 [11/06/08 09:34:59:562]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1213 [11/06/08 09:35:07:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1214 [11/06/08 09:35:07:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1215 [11/06/08 09:35:07:453]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1216 [11/06/08 09:35:08:812]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1217 [11/06/08 09:35:10:562]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1218 [11/06/08 09:35:15:937]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1219 [11/06/08 09:35:15:937]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1220 [11/06/08 09:35:19:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
1221 [11/06/08 09:35:19:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1222 [11/06/08 09:35:19:468]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1223 [11/06/08 09:35:24:750]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1224 [11/06/08 09:35:25:062]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1225 [11/06/08 09:35:25:125]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1226 [11/06/08 09:35:31:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
1227 [11/06/08 09:35:31:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
1228 [11/06/08 09:35:31:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1229 [11/06/08 09:35:34:000]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1230 [11/06/08 09:35:36:062]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1231 [11/06/08 09:35:43:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1232 [11/06/08 09:35:43:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1233 [11/06/08 09:35:43:390]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1234 [11/06/08 09:35:44:875]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x0B', Luminosit: 82.80 Lux
1235 [11/06/08 09:35:45:562]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1236 [11/06/08 09:35:50:312]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1237 [11/06/08 09:35:50:687]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1238 [11/06/08 09:35:50:750]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1239 [11/06/08 09:35:51:500]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1240 [11/06/08 09:35:51:562]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1241 [11/06/08 09:35:55:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xD4 0x00 0x00', Puissance Hall: 106.00 W
1242 [11/06/08 09:35:55:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0x6F 0x00 0x00', Puissance Chambre: 956.00 W
1243 [11/06/08 09:35:55:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x90 0x00 0x00', Puissance Extrieur: 18.00 W
1244 [11/06/08 09:35:57:500]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1245 [11/06/08 09:35:57:500]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1246 [11/06/08 09:35:59:187]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1247 [11/06/08 09:36:02:562]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1248 [11/06/08 09:36:07:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1249 [11/06/08 09:36:07:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
1250 [11/06/08 09:36:07:328]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1251 [11/06/08 09:36:07:500]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1252 [11/06/08 09:36:13:437]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
1253 [11/06/08 09:36:16:312]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1254 [11/06/08 09:36:16:375]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1255 [11/06/08 09:36:16:875]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
1256 [11/06/08 09:36:18:062]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1257 [11/06/08 09:36:18:500]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1258 [11/06/08 09:36:18:562]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1259 [11/06/08 09:36:19:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1260 [11/06/08 09:36:19:328]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1261 [11/06/08 09:36:19:343]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1262 [11/06/08 09:36:23:375]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x04', Temprature chambre: 20.80 C
1263 [11/06/08 09:36:28:500]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1264 [11/06/08 09:36:29:562]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1265 [11/06/08 09:36:31:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1266 [11/06/08 09:36:31:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
1267 [11/06/08 09:36:31:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1268 [11/06/08 09:36:43:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1269 [11/06/08 09:36:43:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
1270 [11/06/08 09:36:43:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1271 [11/06/08 09:36:43:687]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1272 [11/06/08 09:36:44:000]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1273 [11/06/08 09:36:44:000]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1274 [11/06/08 09:36:45:500]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x14', Luminosit: 83.52 Lux
1275 [11/06/08 09:36:53:687]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1276 [11/06/08 09:36:55:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1277 [11/06/08 09:36:55:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1278 [11/06/08 09:36:55:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1279 [11/06/08 09:37:01:187]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
1280 [11/06/08 09:37:04:187]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1281 [11/06/08 09:37:07:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1282 [11/06/08 09:37:07:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
1283 [11/06/08 09:37:07:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1284 [11/06/08 09:37:14:625]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1285 [11/06/08 09:37:16:812]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1286 [11/06/08 09:37:16:812]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1287 [11/06/08 09:37:18:062]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1288 [11/06/08 09:37:19:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
1289 [11/06/08 09:37:19:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1290 [11/06/08 09:37:19:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1291 [11/06/08 09:37:29:062]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1292 [11/06/08 09:37:31:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1293 [11/06/08 09:37:31:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
1294 [11/06/08 09:37:31:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1295 [11/06/08 09:37:32:750]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1296 [11/06/08 09:37:33:125]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1297 [11/06/08 09:37:33:187]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1298 [11/06/08 09:37:41:937]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1299 [11/06/08 09:37:43:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC4 0x00 0x00', Puissance Hall: 98.00 W
1300 [11/06/08 09:37:43:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1301 [11/06/08 09:37:43:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1302 [11/06/08 09:37:43:750]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x01', Soire rception ON/OFF: on
1303 [11/06/08 09:37:43:812]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir chambre: on
1304 [11/06/08 09:37:46:312]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x10', Luminosit: 83.20 Lux
1305 [11/06/08 09:37:54:937]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1306 [11/06/08 09:37:54:937]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
1307 [11/06/08 09:37:55:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Hall: 99.00 W
1308 [11/06/08 09:37:55:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC8 0x00 0x00', Puissance Chambre: 100.00 W
1309 [11/06/08 09:37:55:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1310 [11/06/08 09:38:02:875]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1311 [11/06/08 09:38:05:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Hall: 99.00 W
1312 [11/06/08 09:38:05:890]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC8 0x00 0x00', Puissance Chambre: 100.00 W
1313 [11/06/08 09:38:05:890]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1314 [11/06/08 09:38:17:250]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1315 [11/06/08 09:38:17:250]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1316 [11/06/08 09:38:17:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Hall: 99.00 W
1317 [11/06/08 09:38:17:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC8 0x00 0x00', Puissance Chambre: 100.00 W
1318 [11/06/08 09:38:17:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1319 [11/06/08 09:38:22:062]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x00', Soire rception ON/OFF: off
1320 [11/06/08 09:38:22:750]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1321 [11/06/08 09:38:29:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Hall: 99.00 W
1322 [11/06/08 09:38:29:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC8 0x00 0x00', Puissance Chambre: 100.00 W
1323 [11/06/08 09:38:29:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1324 [11/06/08 09:38:32:250]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1325 [11/06/08 09:38:36:750]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
1326 [11/06/08 09:38:36:750]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir chambre: off
1327 [11/06/08 09:38:41:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1328 [11/06/08 09:38:41:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
1329 [11/06/08 09:38:41:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1330 [11/06/08 09:38:42:750]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1331 [11/06/08 09:38:44:687]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1332 [11/06/08 09:38:46:875]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x2F', Luminosit: 85.68 Lux
1333 [11/06/08 09:38:53:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1334 [11/06/08 09:38:53:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1335 [11/06/08 09:38:53:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1336 [11/06/08 09:39:00:187]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1337 [11/06/08 09:39:00:734]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1338 [11/06/08 09:39:00:750]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1339 [11/06/08 09:39:05:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1340 [11/06/08 09:39:05:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1341 [11/06/08 09:39:05:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1342 [11/06/08 09:39:08:562]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1343 [11/06/08 09:39:08:625]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFD', Temprature chambre: 20.24 C
1344 [11/06/08 09:39:08:625]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1345 [11/06/08 09:39:09:953]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1346 [11/06/08 09:39:10:250]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x01', Soire rception ON/OFF: on
1347 [11/06/08 09:39:10:250]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir chambre: on
1348 [11/06/08 09:39:14:562]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1349 [11/06/08 09:39:14:625]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1350 [11/06/08 09:39:17:500]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1351 [11/06/08 09:39:17:562]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1352 [11/06/08 09:39:17:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xE0 0x00 0x00', Puissance Hall: 112.00 W
1353 [11/06/08 09:39:17:703]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0x5D 0x00 0x00', Puissance Chambre: 884.00 W
1354 [11/06/08 09:39:17:703]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x80 0x00 0x00', Puissance Extrieur: 16.00 W
1355 [11/06/08 09:39:18:437]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x01', Soire rception ON/OFF: on
1356 [11/06/08 09:39:20:062]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x00', Soire rception ON/OFF: off
1357 [11/06/08 09:39:20:375]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1358 [11/06/08 09:39:22:500]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
1359 [11/06/08 09:39:28:500]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1360 [11/06/08 09:39:28:875]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1361 [11/06/08 09:39:29:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Hall: 99.00 W
1362 [11/06/08 09:39:29:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC8 0x00 0x00', Puissance Chambre: 100.00 W
1363 [11/06/08 09:39:29:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1364 [11/06/08 09:39:34:312]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir chambre: off
1365 [11/06/08 09:39:38:187]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
1366 [11/06/08 09:39:38:437]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1367 [11/06/08 09:39:39:312]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1368 [11/06/08 09:39:41:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1369 [11/06/08 09:39:41:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1370 [11/06/08 09:39:41:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1371 [11/06/08 09:39:47:562]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x51', Luminosit: 88.40 Lux
1372 [11/06/08 09:39:49:812]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1373 [11/06/08 09:39:53:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1374 [11/06/08 09:39:53:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
1375 [11/06/08 09:39:53:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1376 [11/06/08 09:40:00:312]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1377 [11/06/08 09:40:05:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
1378 [11/06/08 09:40:05:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
1379 [11/06/08 09:40:05:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1380 [11/06/08 09:40:10:812]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1381 [11/06/08 09:40:12:890]: GroupDataIndicationWrite: 01.01.011, 06/0001, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes hall et repas: on
1382 [11/06/08 09:40:12:937]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat  ON/OFF lampes hall et repas: on
1383 [11/06/08 09:40:13:000]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat  ON/OFF lampes hall et repas: on
1384 [11/06/08 09:40:17:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xFC 0x00 0x00', Puissance Hall: 126.00 W
1385 [11/06/08 09:40:17:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0xBF 0x80 0x00 0x00', Puissance Chambre: -1.00 W
1386 [11/06/08 09:40:17:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xE0 0x00 0x00', Puissance Extrieur: 7.00 W
1387 [11/06/08 09:40:17:937]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1388 [11/06/08 09:40:18:000]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1389 [11/06/08 09:40:20:250]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1390 [11/06/08 09:40:21:312]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1391 [11/06/08 09:40:29:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x14 0x00 0x00', Puissance Hall: 148.00 W
1392 [11/06/08 09:40:29:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
1393 [11/06/08 09:40:29:390]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x00 0x00 0x00', Puissance Extrieur: 8.00 W
1394 [11/06/08 09:40:31:750]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1395 [11/06/08 09:40:38:000]: GroupDataIndicationWrite: 01.01.011, 06/0001, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes hall et repas: off
1396 [11/06/08 09:40:38:062]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat  ON/OFF lampes hall et repas: off
1397 [11/06/08 09:40:38:125]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat  ON/OFF lampes hall et repas: off
1398 [11/06/08 09:40:39:750]: GroupDataIndicationWrite: 01.01.011, 06/0001, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes hall et repas: on
1399 [11/06/08 09:40:39:812]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat  ON/OFF lampes hall et repas: on
1400 [11/06/08 09:40:39:875]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat  ON/OFF lampes hall et repas: on
1401 [11/06/08 09:40:41:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xEC 0x00 0x00', Puissance Hall: 118.00 W
1402 [11/06/08 09:40:41:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Chambre: 1.00 W
1403 [11/06/08 09:40:41:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Extrieur: 2.00 W
1404 [11/06/08 09:40:42:250]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1405 [11/06/08 09:40:46:125]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1406 [11/06/08 09:40:46:187]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1407 [11/06/08 09:40:48:125]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
1408 [11/06/08 09:40:48:125]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x59', Luminosit: 89.04 Lux
1409 [11/06/08 09:40:50:125]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1410 [11/06/08 09:40:50:125]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1411 [11/06/08 09:40:52:750]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1412 [11/06/08 09:40:53:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x48 0x00 0x00', Puissance Hall: 200.00 W
1413 [11/06/08 09:40:53:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0x2F 0x40 0x00', Puissance Chambre: 701.00 W
1414 [11/06/08 09:40:53:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x50 0x00 0x00', Puissance Extrieur: 13.00 W
1415 [11/06/08 09:40:58:062]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1416 [11/06/08 09:41:03:250]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1417 [11/06/08 09:41:05:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x3E 0x00 0x00', Puissance Hall: 190.00 W
1418 [11/06/08 09:41:05:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1419 [11/06/08 09:41:05:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1420 [11/06/08 09:41:13:687]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1421 [11/06/08 09:41:17:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x41 0x00 0x00', Puissance Hall: 193.00 W
1422 [11/06/08 09:41:17:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1423 [11/06/08 09:41:17:296]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1424 [11/06/08 09:41:17:937]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1425 [11/06/08 09:41:18:250]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1426 [11/06/08 09:41:18:312]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1427 [11/06/08 09:41:20:687]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1428 [11/06/08 09:41:29:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x40 0x00 0x00', Puissance Hall: 192.00 W
1429 [11/06/08 09:41:29:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1430 [11/06/08 09:41:29:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1431 [11/06/08 09:41:35:937]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1432 [11/06/08 09:41:36:125]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1433 [11/06/08 09:41:36:187]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1434 [11/06/08 09:41:41:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x49 0x00 0x00', Puissance Hall: 201.00 W
1435 [11/06/08 09:41:41:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1436 [11/06/08 09:41:41:125]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1437 [11/06/08 09:41:45:187]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1438 [11/06/08 09:41:48:750]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x2D', Luminosit: 85.52 Lux
1439 [11/06/08 09:41:49:812]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1440 [11/06/08 09:41:53:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x59 0x00 0x00', Puissance Hall: 217.00 W
1441 [11/06/08 09:41:53:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1442 [11/06/08 09:41:53:062]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Extrieur: 2.00 W
1443 [11/06/08 09:42:06:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x65 0x00 0x00', Puissance Hall: 229.00 W
1444 [11/06/08 09:42:07:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1445 [11/06/08 09:42:07:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Extrieur: 2.00 W
1446 [11/06/08 09:42:18:750]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1447 [11/06/08 09:42:18:750]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1448 [11/06/08 09:42:18:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1449 [11/06/08 09:42:18:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1450 [11/06/08 09:42:18:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1451 [11/06/08 09:42:23:625]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1452 [11/06/08 09:42:23:687]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
1453 [11/06/08 09:42:23:687]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1454 [11/06/08 09:42:30:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x78 0x00 0x00', Puissance Hall: 248.00 W
1455 [11/06/08 09:42:30:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xED 0xA0 0x00', Puissance Chambre: 1901.00 W
1456 [11/06/08 09:42:30:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
1457 [11/06/08 09:42:31:625]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1458 [11/06/08 09:42:31:687]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1459 [11/06/08 09:42:37:562]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1460 [11/06/08 09:42:42:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1461 [11/06/08 09:42:42:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1462 [11/06/08 09:42:42:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1463 [11/06/08 09:42:43:562]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1464 [11/06/08 09:42:47:500]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
1465 [11/06/08 09:42:49:500]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x1C', Luminosit: 84.16 Lux
1466 [11/06/08 09:42:53:000]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x01', Soire rception ON/OFF: on
1467 [11/06/08 09:42:53:062]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir chambre: on
1468 [11/06/08 09:42:53:500]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x04', Temprature chambre: 20.80 C
1469 [11/06/08 09:42:54:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1470 [11/06/08 09:42:54:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1471 [11/06/08 09:42:54:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1472 [11/06/08 09:42:59:500]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
1473 [11/06/08 09:43:01:625]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x00', Soire rception ON/OFF: off
1474 [11/06/08 09:43:01:625]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1475 [11/06/08 09:43:06:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1476 [11/06/08 09:43:06:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xCE 0x00 0x00', Puissance Chambre: 103.00 W
1477 [11/06/08 09:43:06:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1478 [11/06/08 09:43:11:125]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1479 [11/06/08 09:43:16:187]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir chambre: off
1480 [11/06/08 09:43:18:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1481 [11/06/08 09:43:18:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0x8C 0x00 0x00', Puissance Chambre: 70.00 W
1482 [11/06/08 09:43:18:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1483 [11/06/08 09:43:19:187]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1484 [11/06/08 09:43:19:187]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1485 [11/06/08 09:43:21:640]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1486 [11/06/08 09:43:30:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1487 [11/06/08 09:43:30:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
1488 [11/06/08 09:43:30:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Extrieur: 2.00 W
1489 [11/06/08 09:43:32:125]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1490 [11/06/08 09:43:42:625]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1491 [11/06/08 09:43:42:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1492 [11/06/08 09:43:42:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1493 [11/06/08 09:43:42:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1494 [11/06/08 09:43:43:500]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1495 [11/06/08 09:43:50:125]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0xE9', Luminosit: 81.00 Lux
1496 [11/06/08 09:43:54:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1497 [11/06/08 09:43:54:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1498 [11/06/08 09:43:54:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1499 [11/06/08 09:43:55:187]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
1500 [11/06/08 09:43:58:875]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1501 [11/06/08 09:44:01:500]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1502 [11/06/08 09:44:01:562]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1503 [11/06/08 09:44:06:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x68 0x00 0x00', Puissance Hall: 232.00 W
1504 [11/06/08 09:44:06:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1505 [11/06/08 09:44:06:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1506 [11/06/08 09:44:11:937]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1507 [11/06/08 09:44:18:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1508 [11/06/08 09:44:18:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1509 [11/06/08 09:44:18:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1510 [11/06/08 09:44:19:562]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1511 [11/06/08 09:44:19:562]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1512 [11/06/08 09:44:22:437]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1513 [11/06/08 09:44:24:250]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1514 [11/06/08 09:44:27:062]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1515 [11/06/08 09:44:29:062]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1516 [11/06/08 09:44:29:062]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
1517 [11/06/08 09:44:30:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1518 [11/06/08 09:44:30:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1519 [11/06/08 09:44:30:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1520 [11/06/08 09:44:39:375]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1521 [11/06/08 09:44:42:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x2F 0x00 0x00', Puissance Hall: 175.00 W
1522 [11/06/08 09:44:42:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
1523 [11/06/08 09:44:42:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1524 [11/06/08 09:44:50:812]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0xBB', Luminosit: 79.16 Lux
1525 [11/06/08 09:44:54:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
1526 [11/06/08 09:44:54:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
1527 [11/06/08 09:44:54:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1528 [11/06/08 09:45:00:937]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1529 [11/06/08 09:45:06:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
1530 [11/06/08 09:45:06:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
1531 [11/06/08 09:45:06:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1532 [11/06/08 09:45:08:375]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1533 [11/06/08 09:45:08:437]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1534 [11/06/08 09:45:17:000]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1535 [11/06/08 09:45:18:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1536 [11/06/08 09:45:18:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
1537 [11/06/08 09:45:18:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1538 [11/06/08 09:45:19:937]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1539 [11/06/08 09:45:19:953]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1540 [11/06/08 09:45:27:437]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1541 [11/06/08 09:45:30:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1542 [11/06/08 09:45:30:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
1543 [11/06/08 09:45:30:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Extrieur: 2.00 W
1544 [11/06/08 09:45:37:937]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1545 [11/06/08 09:45:40:687]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1546 [11/06/08 09:45:40:750]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1547 [11/06/08 09:45:42:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1548 [11/06/08 09:45:42:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1549 [11/06/08 09:45:42:609]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1550 [11/06/08 09:45:44:687]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1551 [11/06/08 09:45:44:687]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
1552 [11/06/08 09:45:44:750]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1553 [11/06/08 09:45:48:437]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1554 [11/06/08 09:45:51:437]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0xCD', Luminosit: 79.88 Lux
1555 [11/06/08 09:45:52:625]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1556 [11/06/08 09:45:54:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1557 [11/06/08 09:45:54:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1558 [11/06/08 09:45:54:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1559 [11/06/08 09:45:57:750]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1560 [11/06/08 09:46:06:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1561 [11/06/08 09:46:06:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1562 [11/06/08 09:46:06:515]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1563 [11/06/08 09:46:06:625]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1564 [11/06/08 09:46:13:250]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1565 [11/06/08 09:46:14:687]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1566 [11/06/08 09:46:14:750]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1567 [11/06/08 09:46:18:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x4C 0x00 0x00', Puissance Hall: 204.00 W
1568 [11/06/08 09:46:18:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1569 [11/06/08 09:46:18:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Extrieur: 2.00 W
1570 [11/06/08 09:46:20:250]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1571 [11/06/08 09:46:20:312]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1572 [11/06/08 09:46:20:812]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
1573 [11/06/08 09:46:24:062]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1574 [11/06/08 09:46:30:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1575 [11/06/08 09:46:30:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1576 [11/06/08 09:46:30:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1577 [11/06/08 09:46:34:562]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1578 [11/06/08 09:46:42:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1579 [11/06/08 09:46:42:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1580 [11/06/08 09:46:42:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1581 [11/06/08 09:46:44:125]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1582 [11/06/08 09:46:50:375]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1583 [11/06/08 09:46:52:125]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x9D', Luminosit: 77.96 Lux
1584 [11/06/08 09:46:54:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1585 [11/06/08 09:46:54:453]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1586 [11/06/08 09:46:54:453]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1587 [11/06/08 09:46:56:437]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1588 [11/06/08 09:47:05:625]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x16 0x21', Luminosit: 62.76 Lux
1589 [11/06/08 09:47:06:000]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1590 [11/06/08 09:47:06:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1591 [11/06/08 09:47:06:453]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
1592 [11/06/08 09:47:06:468]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1593 [11/06/08 09:47:10:562]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x15 0x61', Luminosit: 55.08 Lux
1594 [11/06/08 09:47:14:500]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x55', Luminosit: 75.08 Lux
1595 [11/06/08 09:47:16:500]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1596 [11/06/08 09:47:18:250]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1597 [11/06/08 09:47:18:312]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1598 [11/06/08 09:47:18:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1599 [11/06/08 09:47:18:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1600 [11/06/08 09:47:18:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1601 [11/06/08 09:47:20:812]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1602 [11/06/08 09:47:20:812]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1603 [11/06/08 09:47:22:250]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1604 [11/06/08 09:47:22:312]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1605 [11/06/08 09:47:22:937]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1606 [11/06/08 09:47:30:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1607 [11/06/08 09:47:30:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
1608 [11/06/08 09:47:30:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Extrieur: 2.00 W
1609 [11/06/08 09:47:33:625]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1610 [11/06/08 09:47:42:125]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1611 [11/06/08 09:47:42:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x68 0x00 0x00', Puissance Hall: 232.00 W
1612 [11/06/08 09:47:42:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
1613 [11/06/08 09:47:42:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1614 [11/06/08 09:47:43:750]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1615 [11/06/08 09:47:44:812]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1616 [11/06/08 09:47:56:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1617 [11/06/08 09:47:56:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1618 [11/06/08 09:47:56:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1619 [11/06/08 09:47:59:937]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1620 [11/06/08 09:48:08:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
1621 [11/06/08 09:48:08:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
1622 [11/06/08 09:48:08:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1623 [11/06/08 09:48:10:515]: GroupDataIndicationWrite: 01.01.005, 03/0002, RoutingCnt=6, PriorityHigh, Data='0x01', Mode Confort ON/OFF: on
1624 [11/06/08 09:48:10:562]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampe chambre: on
1625 [11/06/08 09:48:15:062]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x7D', Luminosit: 76.68 Lux
1626 [11/06/08 09:48:15:937]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1627 [11/06/08 09:48:16:000]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
1628 [11/06/08 09:48:16:000]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1629 [11/06/08 09:48:16:312]: GroupDataIndicationWrite: 01.01.005, 03/0002, RoutingCnt=6, PriorityHigh, Data='0x00', Mode Confort ON/OFF: off
1630 [11/06/08 09:48:16:312]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampe chambre: off
1631 [11/06/08 09:48:17:312]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1632 [11/06/08 09:48:17:375]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1633 [11/06/08 09:48:19:375]: GroupDataIndicationWrite: 01.01.005, 03/0002, RoutingCnt=6, PriorityHigh, Data='0x01', Mode Confort ON/OFF: on
1634 [11/06/08 09:48:19:375]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampe chambre: on
1635 [11/06/08 09:48:20:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x31 0x00 0x00', Puissance Hall: 177.00 W
1636 [11/06/08 09:48:20:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xC9 0xE0 0x00', Puissance Chambre: 1615.00 W
1637 [11/06/08 09:48:20:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0xF0 0x00 0x00', Puissance Extrieur: 30.00 W
1638 [11/06/08 09:48:21:125]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1639 [11/06/08 09:48:21:125]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1640 [11/06/08 09:48:21:937]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1641 [11/06/08 09:48:22:000]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
1642 [11/06/08 09:48:22:000]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1643 [11/06/08 09:48:23:125]: GroupDataIndicationWrite: 01.01.005, 03/0002, RoutingCnt=6, PriorityHigh, Data='0x00', Mode Confort ON/OFF: off
1644 [11/06/08 09:48:23:125]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampe chambre: off
1645 [11/06/08 09:48:23:937]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1646 [11/06/08 09:48:23:937]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
1647 [11/06/08 09:48:24:000]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1648 [11/06/08 09:48:27:812]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1649 [11/06/08 09:48:27:937]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1650 [11/06/08 09:48:27:937]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
1651 [11/06/08 09:48:28:000]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1652 [11/06/08 09:48:29:937]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
1653 [11/06/08 09:48:32:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1654 [11/06/08 09:48:32:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x43 0x9E 0x80 0x00', Puissance Chambre: 317.00 W
1655 [11/06/08 09:48:32:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x00 0x00 0x00', Puissance Extrieur: 8.00 W
1656 [11/06/08 09:48:35:875]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x04', Temprature chambre: 20.80 C
1657 [11/06/08 09:48:36:125]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x10', Luminosit: 72.32 Lux
1658 [11/06/08 09:48:38:312]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1659 [11/06/08 09:48:39:875]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x05', Temprature chambre: 20.88 C
1660 [11/06/08 09:48:39:875]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x8D', Luminosit: 77.32 Lux
1661 [11/06/08 09:48:40:125]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1662 [11/06/08 09:48:42:203]: GroupDataIndicationWrite: 01.01.005, 04/0002, RoutingCnt=6, PriorityLow, Data='0x01', Mode femme de mnage ON/OFF: on
1663 [11/06/08 09:48:42:250]: GroupDataIndicationWrite: 01.01.003, 09/0203, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Gche lectrique: on
1664 [11/06/08 09:48:42:250]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampe chambre: on
1665 [11/06/08 09:48:42:312]: GroupDataIndicationWrite: 01.01.002, 06/0206, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes lit: on
1666 [11/06/08 09:48:43:812]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x06', Temprature chambre: 20.96 C
1667 [11/06/08 09:48:44:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1668 [11/06/08 09:48:44:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
1669 [11/06/08 09:48:44:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1670 [11/06/08 09:48:49:812]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x07', Temprature chambre: 21.04 C
1671 [11/06/08 09:48:55:375]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1672 [11/06/08 09:48:55:625]: GroupDataIndicationWrite: 01.01.005, 04/0002, RoutingCnt=6, PriorityLow, Data='0x00', Mode femme de mnage ON/OFF: off
1673 [11/06/08 09:48:55:625]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampe chambre: off
1674 [11/06/08 09:48:55:625]: GroupDataIndicationWrite: 01.01.002, 06/0206, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes lit: off
1675 [11/06/08 09:48:55:687]: GroupDataIndicationWrite: 01.01.003, 09/0203, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Gche lectrique: off
1676 [11/06/08 09:48:56:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1677 [11/06/08 09:48:56:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x88 0x00 0x00', Puissance Chambre: 17.00 W
1678 [11/06/08 09:48:56:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1679 [11/06/08 09:48:58:812]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1680 [11/06/08 09:48:58:812]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1681 [11/06/08 09:49:03:750]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x09', Temprature chambre: 21.20 C
1682 [11/06/08 09:49:07:625]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1683 [11/06/08 09:49:10:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1684 [11/06/08 09:49:10:265]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
1685 [11/06/08 09:49:10:265]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1686 [11/06/08 09:49:10:500]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x15 0xA8', Luminosit: 57.92 Lux
1687 [11/06/08 09:49:11:687]: GroupDataIndicationWrite: 01.01.005, 04/0002, RoutingCnt=6, PriorityLow, Data='0x01', Mode femme de mnage ON/OFF: on
1688 [11/06/08 09:49:11:687]: GroupDataIndicationWrite: 01.01.003, 09/0203, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Gche lectrique: on
1689 [11/06/08 09:49:11:750]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampe chambre: on
1690 [11/06/08 09:49:11:750]: GroupDataIndicationWrite: 01.01.002, 06/0206, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes lit: on
1691 [11/06/08 09:49:14:062]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x8E', Luminosit: 77.36 Lux
1692 [11/06/08 09:49:14:312]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1693 [11/06/08 09:49:21:562]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1694 [11/06/08 09:49:21:625]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1695 [11/06/08 09:49:22:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1696 [11/06/08 09:49:22:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x88 0x00 0x00', Puissance Chambre: 17.00 W
1697 [11/06/08 09:49:22:265]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1698 [11/06/08 09:49:29:500]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1699 [11/06/08 09:49:31:625]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x07', Temprature chambre: 21.04 C
1700 [11/06/08 09:49:34:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x0B 0x00 0x00', Puissance Hall: 139.00 W
1701 [11/06/08 09:49:34:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x70 0x00 0x00', Puissance Chambre: 15.00 W
1702 [11/06/08 09:49:34:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1703 [11/06/08 09:49:42:125]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
1704 [11/06/08 09:49:46:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
1705 [11/06/08 09:49:46:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x60 0x00 0x00', Puissance Chambre: 14.00 W
1706 [11/06/08 09:49:46:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1707 [11/06/08 09:49:58:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
1708 [11/06/08 09:49:58:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x70 0x00 0x00', Puissance Chambre: 15.00 W
1709 [11/06/08 09:49:58:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1710 [11/06/08 09:50:01:500]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x06', Temprature chambre: 20.96 C
1711 [11/06/08 09:50:10:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
1712 [11/06/08 09:50:10:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x70 0x00 0x00', Puissance Chambre: 15.00 W
1713 [11/06/08 09:50:10:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1714 [11/06/08 09:50:14:562]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x92', Luminosit: 77.52 Lux
1715 [11/06/08 09:50:21:937]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1716 [11/06/08 09:50:21:937]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1717 [11/06/08 09:50:22:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
1718 [11/06/08 09:50:22:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x70 0x00 0x00', Puissance Chambre: 15.00 W
1719 [11/06/08 09:50:22:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1720 [11/06/08 09:50:25:375]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1721 [11/06/08 09:50:25:375]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
1722 [11/06/08 09:50:33:312]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x05', Temprature chambre: 20.88 C
1723 [11/06/08 09:50:34:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
1724 [11/06/08 09:50:34:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x70 0x00 0x00', Puissance Chambre: 15.00 W
1725 [11/06/08 09:50:34:125]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1726 [11/06/08 09:50:46:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x05 0x00 0x00', Puissance Hall: 133.00 W
1727 [11/06/08 09:50:46:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x80 0x00 0x00', Puissance Chambre: 16.00 W
1728 [11/06/08 09:50:46:125]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1729 [11/06/08 09:50:58:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
1730 [11/06/08 09:50:58:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x70 0x00 0x00', Puissance Chambre: 15.00 W
1731 [11/06/08 09:50:58:125]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
1732 [11/06/08 09:51:03:187]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x04', Temprature chambre: 20.80 C
1733 [11/06/08 09:51:04:687]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1734 [11/06/08 09:51:04:750]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1735 [11/06/08 09:51:12:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1736 [11/06/08 09:51:12:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0xA0 0x00 0x00', Puissance Chambre: 20.00 W
1737 [11/06/08 09:51:12:156]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1738 [11/06/08 09:51:13:437]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1739 [11/06/08 09:51:15:250]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x9C', Luminosit: 77.92 Lux
1740 [11/06/08 09:51:21:062]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1741 [11/06/08 09:51:22:312]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1742 [11/06/08 09:51:22:312]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1743 [11/06/08 09:51:24:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6E 0x00 0x00', Puissance Hall: 238.00 W
1744 [11/06/08 09:51:24:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x80 0x00 0x00', Puissance Chambre: 16.00 W
1745 [11/06/08 09:51:24:062]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1746 [11/06/08 09:51:31:062]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
1747 [11/06/08 09:51:34:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1748 [11/06/08 09:51:34:828]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x60 0x00 0x00', Puissance Chambre: 14.00 W
1749 [11/06/08 09:51:34:828]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1750 [11/06/08 09:51:35:375]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1751 [11/06/08 09:51:46:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
1752 [11/06/08 09:51:46:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x88 0x00 0x00', Puissance Chambre: 17.00 W
1753 [11/06/08 09:51:46:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1754 [11/06/08 09:51:56:062]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1755 [11/06/08 09:51:56:125]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1756 [11/06/08 09:51:58:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x2C 0x00 0x00', Puissance Hall: 172.00 W
1757 [11/06/08 09:51:58:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x80 0x00 0x00', Puissance Chambre: 16.00 W
1758 [11/06/08 09:51:58:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1759 [11/06/08 09:51:58:937]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1760 [11/06/08 09:52:05:875]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1761 [11/06/08 09:52:10:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1762 [11/06/08 09:52:10:703]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x80 0x00 0x00', Puissance Chambre: 16.00 W
1763 [11/06/08 09:52:10:703]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1764 [11/06/08 09:52:16:000]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x85', Luminosit: 77.00 Lux
1765 [11/06/08 09:52:16:375]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1766 [11/06/08 09:52:22:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1767 [11/06/08 09:52:22:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x90 0x00 0x00', Puissance Chambre: 18.00 W
1768 [11/06/08 09:52:22:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1769 [11/06/08 09:52:22:812]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1770 [11/06/08 09:52:22:812]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1771 [11/06/08 09:52:22:812]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1772 [11/06/08 09:52:22:875]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
1773 [11/06/08 09:52:24:750]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1774 [11/06/08 09:52:25:812]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1775 [11/06/08 09:52:28:750]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1776 [11/06/08 09:52:34:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1777 [11/06/08 09:52:34:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x80 0x00 0x00', Puissance Chambre: 16.00 W
1778 [11/06/08 09:52:34:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1779 [11/06/08 09:52:35:250]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1780 [11/06/08 09:52:39:000]: GroupDataConfirmationWrite: 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Sonnerie ON/OFF: on
1781 [11/06/08 09:52:39:078]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
1782 [11/06/08 09:52:40:625]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
1783 [11/06/08 09:52:42:812]: GroupDataConfirmationWrite: 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Sonnerie ON/OFF: off
1784 [11/06/08 09:52:42:875]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
1785 [11/06/08 09:52:44:062]: GroupDataConfirmationWrite: 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Sonnerie ON/OFF: on
1786 [11/06/08 09:52:44:125]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
1787 [11/06/08 09:52:45:062]: GroupDataConfirmationWrite: 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Sonnerie ON/OFF: off
1788 [11/06/08 09:52:45:125]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
1789 [11/06/08 09:52:45:875]: GroupDataConfirmationWrite: 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Sonnerie ON/OFF: on
1790 [11/06/08 09:52:45:937]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
1791 [11/06/08 09:52:46:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1792 [11/06/08 09:52:46:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x88 0x00 0x00', Puissance Chambre: 17.00 W
1793 [11/06/08 09:52:46:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1794 [11/06/08 09:52:46:875]: GroupDataConfirmationWrite: 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Sonnerie ON/OFF: off
1795 [11/06/08 09:52:46:937]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
1796 [11/06/08 09:52:47:625]: GroupDataConfirmationWrite: 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Sonnerie ON/OFF: on
1797 [11/06/08 09:52:47:687]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
1798 [11/06/08 09:52:48:687]: GroupDataConfirmationWrite: 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Sonnerie ON/OFF: off
1799 [11/06/08 09:52:48:750]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
1800 [11/06/08 09:52:56:437]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
1801 [11/06/08 09:52:58:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x5E 0x00 0x00', Puissance Hall: 222.00 W
1802 [11/06/08 09:52:58:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x80 0x00 0x00', Puissance Chambre: 16.00 W
1803 [11/06/08 09:52:58:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1804 [11/06/08 09:53:00:625]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
1805 [11/06/08 09:53:03:437]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
1806 [11/06/08 09:53:10:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
1807 [11/06/08 09:53:10:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x60 0x00 0x00', Puissance Chambre: 14.00 W
1808 [11/06/08 09:53:10:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
1809 [11/06/08 09:53:11:250]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
1810 [11/06/08 09:53:11:250]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
1811 [11/06/08 09:53:16:562]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x51', Luminosit: 74.92 Lux
1812 [11/06/08 09:53:20:500]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1813 [11/06/08 09:53:20:625]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1814 [11/06/08 09:53:22:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1815 [11/06/08 09:53:22:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x80 0x00 0x00', Puissance Chambre: 16.00 W
1816 [11/06/08 09:53:22:468]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1817 [11/06/08 09:53:23:062]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1818 [11/06/08 09:53:23:125]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1819 [11/06/08 09:53:26:500]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1820 [11/06/08 09:53:26:562]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1821 [11/06/08 09:53:34:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1822 [11/06/08 09:53:34:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x80 0x00 0x00', Puissance Chambre: 16.00 W
1823 [11/06/08 09:53:34:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1824 [11/06/08 09:53:38:437]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1825 [11/06/08 09:53:44:437]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1826 [11/06/08 09:53:46:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1827 [11/06/08 09:53:46:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x90 0x00 0x00', Puissance Chambre: 18.00 W
1828 [11/06/08 09:53:46:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
1829 [11/06/08 09:53:46:625]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x01', Soire rception ON/OFF: on
1830 [11/06/08 09:53:46:750]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir chambre: on
1831 [11/06/08 09:53:58:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
1832 [11/06/08 09:53:58:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE0 0x00 0x00', Puissance Chambre: 112.00 W
1833 [11/06/08 09:53:58:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1834 [11/06/08 09:54:10:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1835 [11/06/08 09:54:10:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1836 [11/06/08 09:54:10:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1837 [11/06/08 09:54:17:250]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x19', Luminosit: 72.68 Lux
1838 [11/06/08 09:54:22:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1839 [11/06/08 09:54:22:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1840 [11/06/08 09:54:22:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1841 [11/06/08 09:54:23:562]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1842 [11/06/08 09:54:23:562]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1843 [11/06/08 09:54:34:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1844 [11/06/08 09:54:34:140]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1845 [11/06/08 09:54:34:140]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1846 [11/06/08 09:54:46:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1847 [11/06/08 09:54:46:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE6 0x00 0x00', Puissance Chambre: 115.00 W
1848 [11/06/08 09:54:46:156]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1849 [11/06/08 09:54:50:125]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1850 [11/06/08 09:54:58:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1851 [11/06/08 09:54:58:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1852 [11/06/08 09:54:58:062]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1853 [11/06/08 09:54:58:062]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1854 [11/06/08 09:54:58:140]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1855 [11/06/08 09:55:02:062]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1856 [11/06/08 09:55:02:125]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1857 [11/06/08 09:55:09:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
1858 [11/06/08 09:55:10:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
1859 [11/06/08 09:55:10:015]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1860 [11/06/08 09:55:14:000]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1861 [11/06/08 09:55:17:937]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x16 0xEF', Luminosit: 71.00 Lux
1862 [11/06/08 09:55:21:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1863 [11/06/08 09:55:21:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1864 [11/06/08 09:55:22:015]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1865 [11/06/08 09:55:23:937]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1866 [11/06/08 09:55:24:000]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1867 [11/06/08 09:55:27:937]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
1868 [11/06/08 09:55:33:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
1869 [11/06/08 09:55:33:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1870 [11/06/08 09:55:33:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1871 [11/06/08 09:55:45:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6F 0x00 0x00', Puissance Hall: 239.00 W
1872 [11/06/08 09:55:45:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1873 [11/06/08 09:55:45:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1874 [11/06/08 09:55:57:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1875 [11/06/08 09:55:57:812]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1876 [11/06/08 09:55:57:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE0 0x00 0x00', Puissance Chambre: 112.00 W
1877 [11/06/08 09:55:57:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1878 [11/06/08 09:56:09:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
1879 [11/06/08 09:56:09:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE8 0x00 0x00', Puissance Chambre: 116.00 W
1880 [11/06/08 09:56:09:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1881 [11/06/08 09:56:18:562]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x16 0xE5', Luminosit: 70.60 Lux
1882 [11/06/08 09:56:21:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
1883 [11/06/08 09:56:21:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE8 0x00 0x00', Puissance Chambre: 116.00 W
1884 [11/06/08 09:56:21:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1885 [11/06/08 09:56:24:312]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1886 [11/06/08 09:56:24:312]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1887 [11/06/08 09:56:24:750]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
1888 [11/06/08 09:56:31:625]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1889 [11/06/08 09:56:33:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
1890 [11/06/08 09:56:33:703]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE6 0x00 0x00', Puissance Chambre: 115.00 W
1891 [11/06/08 09:56:33:703]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1892 [11/06/08 09:56:35:625]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1893 [11/06/08 09:56:35:625]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1894 [11/06/08 09:56:39:562]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1895 [11/06/08 09:56:39:625]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1896 [11/06/08 09:56:45:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6F 0x00 0x00', Puissance Hall: 239.00 W
1897 [11/06/08 09:56:45:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
1898 [11/06/08 09:56:45:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1899 [11/06/08 09:56:53:500]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1900 [11/06/08 09:56:57:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1901 [11/06/08 09:56:57:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE6 0x00 0x00', Puissance Chambre: 115.00 W
1902 [11/06/08 09:56:57:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1903 [11/06/08 09:57:03:437]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
1904 [11/06/08 09:57:09:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1905 [11/06/08 09:57:09:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1906 [11/06/08 09:57:09:656]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1907 [11/06/08 09:57:19:125]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x16 0xCA', Luminosit: 69.52 Lux
1908 [11/06/08 09:57:23:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1909 [11/06/08 09:57:23:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1910 [11/06/08 09:57:23:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1911 [11/06/08 09:57:24:687]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1912 [11/06/08 09:57:24:750]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1913 [11/06/08 09:57:35:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1914 [11/06/08 09:57:35:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1915 [11/06/08 09:57:35:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1916 [11/06/08 09:57:41:312]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1917 [11/06/08 09:57:47:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
1918 [11/06/08 09:57:47:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
1919 [11/06/08 09:57:47:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1920 [11/06/08 09:57:59:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1921 [11/06/08 09:57:59:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
1922 [11/06/08 09:57:59:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1923 [11/06/08 09:58:11:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1924 [11/06/08 09:58:11:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
1925 [11/06/08 09:58:11:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1926 [11/06/08 09:58:15:125]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1927 [11/06/08 09:58:15:125]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1928 [11/06/08 09:58:15:187]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1929 [11/06/08 09:58:17:125]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1930 [11/06/08 09:58:17:187]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1931 [11/06/08 09:58:19:937]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x16 0xD2', Luminosit: 69.84 Lux
1932 [11/06/08 09:58:23:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1933 [11/06/08 09:58:23:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1934 [11/06/08 09:58:23:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Extrieur: 5.00 W
1935 [11/06/08 09:58:25:125]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1936 [11/06/08 09:58:25:187]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1937 [11/06/08 09:58:35:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1938 [11/06/08 09:58:35:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1939 [11/06/08 09:58:35:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Extrieur: 5.00 W
1940 [11/06/08 09:58:47:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1941 [11/06/08 09:58:47:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1942 [11/06/08 09:58:47:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1943 [11/06/08 09:58:59:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1944 [11/06/08 09:58:59:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
1945 [11/06/08 09:58:59:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1946 [11/06/08 09:59:11:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1947 [11/06/08 09:59:11:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1948 [11/06/08 09:59:11:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1949 [11/06/08 09:59:20:375]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x24', Luminosit: 73.12 Lux
1950 [11/06/08 09:59:23:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1951 [11/06/08 09:59:23:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
1952 [11/06/08 09:59:23:453]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Extrieur: 5.00 W
1953 [11/06/08 09:59:25:437]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1954 [11/06/08 09:59:25:500]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1955 [11/06/08 09:59:35:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1956 [11/06/08 09:59:35:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
1957 [11/06/08 09:59:35:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1958 [11/06/08 09:59:46:062]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
1959 [11/06/08 09:59:47:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1960 [11/06/08 09:59:47:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1961 [11/06/08 09:59:47:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1962 [11/06/08 09:59:50:687]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
1963 [11/06/08 09:59:52:687]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
1964 [11/06/08 09:59:52:750]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
1965 [11/06/08 09:59:56:625]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
1966 [11/06/08 09:59:56:687]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
1967 [11/06/08 09:59:59:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x78 0x00 0x00', Puissance Hall: 248.00 W
1968 [11/06/08 09:59:59:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xD5 0xC0 0x00', Puissance Chambre: 1710.00 W
1969 [11/06/08 09:59:59:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x00 0x00 0x00', Puissance Extrieur: 32.00 W
1970 [11/06/08 10:00:04:625]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1971 [11/06/08 10:00:11:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1972 [11/06/08 10:00:11:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1973 [11/06/08 10:00:11:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1974 [11/06/08 10:00:18:562]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
1975 [11/06/08 10:00:21:187]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x78', Luminosit: 76.48 Lux
1976 [11/06/08 10:00:23:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1977 [11/06/08 10:00:23:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
1978 [11/06/08 10:00:23:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1979 [11/06/08 10:00:25:875]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1980 [11/06/08 10:00:25:937]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
1981 [11/06/08 10:00:35:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
1982 [11/06/08 10:00:35:328]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
1983 [11/06/08 10:00:35:328]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1984 [11/06/08 10:00:47:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1985 [11/06/08 10:00:47:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
1986 [11/06/08 10:00:47:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Extrieur: 5.00 W
1987 [11/06/08 10:00:59:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
1988 [11/06/08 10:00:59:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1989 [11/06/08 10:00:59:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Extrieur: 5.00 W
1990 [11/06/08 10:01:02:312]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
1991 [11/06/08 10:01:11:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1992 [11/06/08 10:01:11:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1993 [11/06/08 10:01:11:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1994 [11/06/08 10:01:21:812]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x9C', Luminosit: 77.92 Lux
1995 [11/06/08 10:01:23:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
1996 [11/06/08 10:01:23:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
1997 [11/06/08 10:01:23:281]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
1998 [11/06/08 10:01:26:375]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
1999 [11/06/08 10:01:26:375]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2000 [11/06/08 10:01:30:187]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2001 [11/06/08 10:01:30:312]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2002 [11/06/08 10:01:34:187]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2003 [11/06/08 10:01:34:250]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2004 [11/06/08 10:01:35:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x79 0x00 0x00', Puissance Hall: 249.00 W
2005 [11/06/08 10:01:35:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xFB 0x40 0x00', Puissance Chambre: 2010.00 W
2006 [11/06/08 10:01:35:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x18 0x00 0x00', Puissance Extrieur: 38.00 W
2007 [11/06/08 10:01:47:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
2008 [11/06/08 10:01:47:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
2009 [11/06/08 10:01:47:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2010 [11/06/08 10:01:54:062]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
2011 [11/06/08 10:01:59:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
2012 [11/06/08 10:01:59:203]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
2013 [11/06/08 10:01:59:203]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2014 [11/06/08 10:02:11:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
2015 [11/06/08 10:02:11:203]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
2016 [11/06/08 10:02:11:203]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2017 [11/06/08 10:02:22:375]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x94', Luminosit: 77.60 Lux
2018 [11/06/08 10:02:23:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
2019 [11/06/08 10:02:23:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
2020 [11/06/08 10:02:23:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2021 [11/06/08 10:02:26:625]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2022 [11/06/08 10:02:26:687]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2023 [11/06/08 10:02:35:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
2024 [11/06/08 10:02:35:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
2025 [11/06/08 10:02:35:125]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2026 [11/06/08 10:02:47:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
2027 [11/06/08 10:02:47:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
2028 [11/06/08 10:02:47:125]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2029 [11/06/08 10:02:51:812]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
2030 [11/06/08 10:02:59:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
2031 [11/06/08 10:02:59:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
2032 [11/06/08 10:02:59:125]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2033 [11/06/08 10:03:07:375]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
2034 [11/06/08 10:03:07:750]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2035 [11/06/08 10:03:07:812]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2036 [11/06/08 10:03:11:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x70 0x00 0x00', Puissance Hall: 240.00 W
2037 [11/06/08 10:03:11:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0x0C 0x00 0x00', Puissance Chambre: 560.00 W
2038 [11/06/08 10:03:11:140]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x40 0x00 0x00', Puissance Extrieur: 12.00 W
2039 [11/06/08 10:03:11:687]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2040 [11/06/08 10:03:11:812]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2041 [11/06/08 10:03:23:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
2042 [11/06/08 10:03:23:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE6 0x00 0x00', Puissance Chambre: 115.00 W
2043 [11/06/08 10:03:23:062]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2044 [11/06/08 10:03:23:125]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0xAF', Luminosit: 78.68 Lux
2045 [11/06/08 10:03:23:687]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
2046 [11/06/08 10:03:27:062]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2047 [11/06/08 10:03:27:062]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2048 [11/06/08 10:03:35:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
2049 [11/06/08 10:03:35:078]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE8 0x00 0x00', Puissance Chambre: 116.00 W
2050 [11/06/08 10:03:35:078]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2051 [11/06/08 10:03:39:562]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
2052 [11/06/08 10:03:47:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6E 0x00 0x00', Puissance Hall: 238.00 W
2053 [11/06/08 10:03:47:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE6 0x00 0x00', Puissance Chambre: 115.00 W
2054 [11/06/08 10:03:47:093]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2055 [11/06/08 10:03:59:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
2056 [11/06/08 10:03:59:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
2057 [11/06/08 10:03:59:062]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Extrieur: 5.00 W
2058 [11/06/08 10:04:11:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
2059 [11/06/08 10:04:11:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
2060 [11/06/08 10:04:11:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2061 [11/06/08 10:04:17:375]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
2062 [11/06/08 10:04:22:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
2063 [11/06/08 10:04:23:015]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
2064 [11/06/08 10:04:23:015]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2065 [11/06/08 10:04:23:687]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0xC5', Luminosit: 79.56 Lux
2066 [11/06/08 10:04:27:437]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2067 [11/06/08 10:04:27:500]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2068 [11/06/08 10:04:34:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
2069 [11/06/08 10:04:34:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE0 0x00 0x00', Puissance Chambre: 112.00 W
2070 [11/06/08 10:04:35:046]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2071 [11/06/08 10:04:46:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6E 0x00 0x00', Puissance Hall: 238.00 W
2072 [11/06/08 10:04:46:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
2073 [11/06/08 10:04:46:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2074 [11/06/08 10:04:47:250]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2075 [11/06/08 10:04:47:312]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2076 [11/06/08 10:04:49:250]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2077 [11/06/08 10:04:49:312]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2078 [11/06/08 10:04:58:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6D 0x00 0x00', Puissance Hall: 237.00 W
2079 [11/06/08 10:04:58:953]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
2080 [11/06/08 10:04:58:953]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2081 [11/06/08 10:05:00:312]: GroupDataConfirmationWrite: 04/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Soire rception ON/OFF: off
2082 [11/06/08 10:05:09:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6E 0x00 0x00', Puissance Hall: 238.00 W
2083 [11/06/08 10:05:09:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
2084 [11/06/08 10:05:09:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2085 [11/06/08 10:05:10:312]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2086 [11/06/08 10:05:14:562]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir chambre: off
2087 [11/06/08 10:05:20:687]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2088 [11/06/08 10:05:21:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
2089 [11/06/08 10:05:21:640]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x88 0x00 0x00', Puissance Chambre: 17.00 W
2090 [11/06/08 10:05:21:640]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
2091 [11/06/08 10:05:23:687]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
2092 [11/06/08 10:05:24:375]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x78', Luminosit: 76.48 Lux
2093 [11/06/08 10:05:27:937]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2094 [11/06/08 10:05:27:937]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2095 [11/06/08 10:05:35:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
2096 [11/06/08 10:05:35:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x88 0x00 0x00', Puissance Chambre: 17.00 W
2097 [11/06/08 10:05:35:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
2098 [11/06/08 10:05:38:000]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
2099 [11/06/08 10:05:47:000]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
2100 [11/06/08 10:05:47:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2101 [11/06/08 10:05:47:578]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x70 0x00 0x00', Puissance Chambre: 15.00 W
2102 [11/06/08 10:05:47:593]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2103 [11/06/08 10:05:47:875]: GroupDataIndicationWrite: 01.01.005, 04/0002, RoutingCnt=6, PriorityLow, Data='0x00', Mode femme de mnage ON/OFF: off
2104 [11/06/08 10:05:47:875]: GroupDataIndicationWrite: 01.01.003, 09/0203, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Gche lectrique: off
2105 [11/06/08 10:05:47:937]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampe chambre: off
2106 [11/06/08 10:05:47:937]: GroupDataIndicationWrite: 01.01.002, 06/0206, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes lit: off
2107 [11/06/08 10:05:53:375]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2108 [11/06/08 10:05:53:437]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
2109 [11/06/08 10:05:59:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
2110 [11/06/08 10:05:59:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2111 [11/06/08 10:05:59:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
2112 [11/06/08 10:06:02:625]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2113 [11/06/08 10:06:11:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
2114 [11/06/08 10:06:11:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
2115 [11/06/08 10:06:11:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
2116 [11/06/08 10:06:13:062]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2117 [11/06/08 10:06:19:250]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
2118 [11/06/08 10:06:23:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6A 0x00 0x00', Puissance Hall: 234.00 W
2119 [11/06/08 10:06:23:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
2120 [11/06/08 10:06:23:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
2121 [11/06/08 10:06:24:812]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2122 [11/06/08 10:06:24:875]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2123 [11/06/08 10:06:25:000]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x52', Luminosit: 74.96 Lux
2124 [11/06/08 10:06:28:250]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2125 [11/06/08 10:06:28:250]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2126 [11/06/08 10:06:28:687]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
2127 [11/06/08 10:06:28:812]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2128 [11/06/08 10:06:28:812]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2129 [11/06/08 10:06:33:500]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
2130 [11/06/08 10:06:35:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
2131 [11/06/08 10:06:35:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2132 [11/06/08 10:06:35:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
2133 [11/06/08 10:06:44:687]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
2134 [11/06/08 10:06:47:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2135 [11/06/08 10:06:47:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2136 [11/06/08 10:06:47:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2137 [11/06/08 10:06:59:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2138 [11/06/08 10:06:59:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2139 [11/06/08 10:06:59:328]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2140 [11/06/08 10:07:10:750]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2141 [11/06/08 10:07:10:812]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
2142 [11/06/08 10:07:11:296]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2143 [11/06/08 10:07:11:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2144 [11/06/08 10:07:11:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
2145 [11/06/08 10:07:20:187]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2146 [11/06/08 10:07:23:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6C 0x00 0x00', Puissance Hall: 236.00 W
2147 [11/06/08 10:07:23:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
2148 [11/06/08 10:07:23:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
2149 [11/06/08 10:07:25:750]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x41', Luminosit: 74.28 Lux
2150 [11/06/08 10:07:28:687]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2151 [11/06/08 10:07:28:750]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2152 [11/06/08 10:07:29:500]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
2153 [11/06/08 10:07:30:812]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2154 [11/06/08 10:07:35:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6B 0x00 0x00', Puissance Hall: 235.00 W
2155 [11/06/08 10:07:35:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
2156 [11/06/08 10:07:35:156]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x18 0x00 0x00', Puissance Extrieur: 38.00 W
2157 [11/06/08 10:07:35:375]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0xC0', Luminosit: 79.36 Lux
2158 [11/06/08 10:07:41:187]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2159 [11/06/08 10:07:41:312]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
2160 [11/06/08 10:07:47:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6E 0x00 0x00', Puissance Hall: 238.00 W
2161 [11/06/08 10:07:47:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Chambre: 5.00 W
2162 [11/06/08 10:07:47:062]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x18 0x00 0x00', Puissance Extrieur: 38.00 W
2163 [11/06/08 10:07:56:687]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
2164 [11/06/08 10:07:59:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x51 0x00 0x00', Puissance Hall: 209.00 W
2165 [11/06/08 10:07:59:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2166 [11/06/08 10:07:59:062]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x18 0x00 0x00', Puissance Extrieur: 38.00 W
2167 [11/06/08 10:08:00:312]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
2168 [11/06/08 10:08:02:312]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2169 [11/06/08 10:08:02:375]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2170 [11/06/08 10:08:06:312]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2171 [11/06/08 10:08:06:375]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2172 [11/06/08 10:08:10:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2173 [11/06/08 10:08:11:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2174 [11/06/08 10:08:11:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x14 0x00 0x00', Puissance Extrieur: 37.00 W
2175 [11/06/08 10:08:14:250]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
2176 [11/06/08 10:08:22:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2177 [11/06/08 10:08:22:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2178 [11/06/08 10:08:23:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2179 [11/06/08 10:08:26:250]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
2180 [11/06/08 10:08:29:062]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2181 [11/06/08 10:08:29:062]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2182 [11/06/08 10:08:34:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2183 [11/06/08 10:08:34:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2184 [11/06/08 10:08:34:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2185 [11/06/08 10:08:35:937]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x86', Luminosit: 77.04 Lux
2186 [11/06/08 10:08:46:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2187 [11/06/08 10:08:46:890]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2188 [11/06/08 10:08:46:890]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2189 [11/06/08 10:08:58:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2190 [11/06/08 10:08:58:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2191 [11/06/08 10:08:58:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2192 [11/06/08 10:09:10:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2193 [11/06/08 10:09:10:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2194 [11/06/08 10:09:10:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2195 [11/06/08 10:09:21:937]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
2196 [11/06/08 10:09:22:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2197 [11/06/08 10:09:22:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2198 [11/06/08 10:09:22:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2199 [11/06/08 10:09:29:437]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2200 [11/06/08 10:09:29:437]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2201 [11/06/08 10:09:34:625]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2202 [11/06/08 10:09:34:703]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2203 [11/06/08 10:09:34:703]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2204 [11/06/08 10:09:36:437]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0x83', Luminosit: 76.92 Lux
2205 [11/06/08 10:09:39:875]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2206 [11/06/08 10:09:39:937]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2207 [11/06/08 10:09:41:875]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2208 [11/06/08 10:09:41:937]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2209 [11/06/08 10:09:46:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2210 [11/06/08 10:09:46:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2211 [11/06/08 10:09:46:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2212 [11/06/08 10:09:49:953]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
2213 [11/06/08 10:09:58:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2214 [11/06/08 10:09:58:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2215 [11/06/08 10:09:58:656]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2216 [11/06/08 10:10:10:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2217 [11/06/08 10:10:10:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2218 [11/06/08 10:10:10:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2219 [11/06/08 10:10:22:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2220 [11/06/08 10:10:22:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2221 [11/06/08 10:10:22:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2222 [11/06/08 10:10:29:812]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2223 [11/06/08 10:10:29:875]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2224 [11/06/08 10:10:34:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2225 [11/06/08 10:10:34:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2226 [11/06/08 10:10:34:531]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2227 [11/06/08 10:10:37:250]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0xB0', Luminosit: 78.72 Lux
2228 [11/06/08 10:10:46:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2229 [11/06/08 10:10:46:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2230 [11/06/08 10:10:46:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2231 [11/06/08 10:10:58:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2232 [11/06/08 10:10:58:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2233 [11/06/08 10:10:58:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2234 [11/06/08 10:11:10:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2235 [11/06/08 10:11:10:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2236 [11/06/08 10:11:10:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2237 [11/06/08 10:11:11:437]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
2238 [11/06/08 10:11:19:375]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2239 [11/06/08 10:11:19:437]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2240 [11/06/08 10:11:22:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x15 0x00 0x00', Puissance Hall: 149.00 W
2241 [11/06/08 10:11:22:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0x63 0x80 0x00', Puissance Chambre: 910.00 W
2242 [11/06/08 10:11:22:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x54 0x00 0x00', Puissance Extrieur: 53.00 W
2243 [11/06/08 10:11:23:375]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2244 [11/06/08 10:11:23:437]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2245 [11/06/08 10:11:30:250]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2246 [11/06/08 10:11:30:312]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2247 [11/06/08 10:11:34:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2248 [11/06/08 10:11:34:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2249 [11/06/08 10:11:34:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2250 [11/06/08 10:11:37:750]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x17 0xF2', Luminosit: 81.36 Lux
2251 [11/06/08 10:11:39:312]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
2252 [11/06/08 10:11:46:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2253 [11/06/08 10:11:46:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2254 [11/06/08 10:11:46:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2255 [11/06/08 10:11:58:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2256 [11/06/08 10:11:58:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2257 [11/06/08 10:11:58:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2258 [11/06/08 10:12:10:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2259 [11/06/08 10:12:10:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2260 [11/06/08 10:12:10:406]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2261 [11/06/08 10:12:22:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x09 0x00 0x00', Puissance Hall: 137.00 W
2262 [11/06/08 10:12:22:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2263 [11/06/08 10:12:22:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2264 [11/06/08 10:12:30:750]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2265 [11/06/08 10:12:30:812]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2266 [11/06/08 10:12:34:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2267 [11/06/08 10:12:34:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2268 [11/06/08 10:12:34:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2269 [11/06/08 10:12:38:437]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x03', Luminosit: 82.16 Lux
2270 [11/06/08 10:12:46:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2271 [11/06/08 10:12:46:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2272 [11/06/08 10:12:46:328]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2273 [11/06/08 10:12:56:937]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2274 [11/06/08 10:12:57:000]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2275 [11/06/08 10:12:58:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2276 [11/06/08 10:12:58:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2277 [11/06/08 10:12:58:359]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2278 [11/06/08 10:12:58:937]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2279 [11/06/08 10:12:58:937]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2280 [11/06/08 10:13:10:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2281 [11/06/08 10:13:10:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2282 [11/06/08 10:13:10:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2283 [11/06/08 10:13:11:312]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
2284 [11/06/08 10:13:22:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
2285 [11/06/08 10:13:22:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2286 [11/06/08 10:13:22:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2287 [11/06/08 10:13:31:062]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2288 [11/06/08 10:13:31:062]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2289 [11/06/08 10:13:34:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x09 0x00 0x00', Puissance Hall: 137.00 W
2290 [11/06/08 10:13:34:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2291 [11/06/08 10:13:34:265]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2292 [11/06/08 10:13:39:062]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x0F', Luminosit: 83.12 Lux
2293 [11/06/08 10:13:46:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2294 [11/06/08 10:13:46:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2295 [11/06/08 10:13:46:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2296 [11/06/08 10:13:58:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
2297 [11/06/08 10:13:58:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2298 [11/06/08 10:13:58:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2299 [11/06/08 10:14:10:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2300 [11/06/08 10:14:10:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2301 [11/06/08 10:14:10:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2302 [11/06/08 10:14:10:562]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
2303 [11/06/08 10:14:22:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2304 [11/06/08 10:14:22:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2305 [11/06/08 10:14:22:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2306 [11/06/08 10:14:31:500]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2307 [11/06/08 10:14:31:562]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2308 [11/06/08 10:14:34:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2309 [11/06/08 10:14:34:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2310 [11/06/08 10:14:34:125]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2311 [11/06/08 10:14:36:437]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2312 [11/06/08 10:14:36:500]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2313 [11/06/08 10:14:39:812]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x1C', Luminosit: 84.16 Lux
2314 [11/06/08 10:14:40:437]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2315 [11/06/08 10:14:40:500]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2316 [11/06/08 10:14:46:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2317 [11/06/08 10:14:46:140]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2318 [11/06/08 10:14:46:140]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2319 [11/06/08 10:14:54:375]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
2320 [11/06/08 10:14:58:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2321 [11/06/08 10:14:58:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2322 [11/06/08 10:14:58:125]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2323 [11/06/08 10:15:10:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2324 [11/06/08 10:15:10:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2325 [11/06/08 10:15:10:156]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2326 [11/06/08 10:15:22:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2327 [11/06/08 10:15:22:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2328 [11/06/08 10:15:22:062]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2329 [11/06/08 10:15:31:812]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2330 [11/06/08 10:15:31:812]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2331 [11/06/08 10:15:34:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2332 [11/06/08 10:15:34:078]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2333 [11/06/08 10:15:34:078]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2334 [11/06/08 10:15:40:437]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x3A', Luminosit: 86.56 Lux
2335 [11/06/08 10:15:46:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2336 [11/06/08 10:15:46:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2337 [11/06/08 10:15:46:078]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2338 [11/06/08 10:15:58:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2339 [11/06/08 10:15:58:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2340 [11/06/08 10:15:58:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2341 [11/06/08 10:16:09:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2342 [11/06/08 10:16:10:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2343 [11/06/08 10:16:10:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2344 [11/06/08 10:16:14:000]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2345 [11/06/08 10:16:14:062]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2346 [11/06/08 10:16:16:000]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2347 [11/06/08 10:16:16:000]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2348 [11/06/08 10:16:21:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2349 [11/06/08 10:16:22:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2350 [11/06/08 10:16:22:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2351 [11/06/08 10:16:32:187]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2352 [11/06/08 10:16:32:250]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2353 [11/06/08 10:16:32:625]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
2354 [11/06/08 10:16:33:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2355 [11/06/08 10:16:33:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2356 [11/06/08 10:16:34:046]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2357 [11/06/08 10:16:41:062]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x60', Luminosit: 89.60 Lux
2358 [11/06/08 10:16:45:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2359 [11/06/08 10:16:45:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2360 [11/06/08 10:16:45:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2361 [11/06/08 10:16:57:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2362 [11/06/08 10:16:57:953]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2363 [11/06/08 10:16:57:953]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2364 [11/06/08 10:17:09:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2365 [11/06/08 10:17:09:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2366 [11/06/08 10:17:09:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2367 [11/06/08 10:17:21:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2368 [11/06/08 10:17:21:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2369 [11/06/08 10:17:21:968]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2370 [11/06/08 10:17:24:062]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x9F', Luminosit: 94.64 Lux
2371 [11/06/08 10:17:32:687]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2372 [11/06/08 10:17:32:687]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2373 [11/06/08 10:17:33:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2374 [11/06/08 10:17:33:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2375 [11/06/08 10:17:33:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2376 [11/06/08 10:17:35:625]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
2377 [11/06/08 10:17:45:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
2378 [11/06/08 10:17:45:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2379 [11/06/08 10:17:45:875]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2380 [11/06/08 10:17:51:500]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2381 [11/06/08 10:17:51:625]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2382 [11/06/08 10:17:55:500]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2383 [11/06/08 10:17:55:562]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2384 [11/06/08 10:17:59:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x13 0x00 0x00', Puissance Hall: 147.00 W
2385 [11/06/08 10:17:59:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0x31 0xC0 0x00', Puissance Chambre: 711.00 W
2386 [11/06/08 10:17:59:890]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x44 0x00 0x00', Puissance Extrieur: 49.00 W
2387 [11/06/08 10:18:09:437]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
2388 [11/06/08 10:18:11:687]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0xDC', Luminosit: 99.52 Lux
2389 [11/06/08 10:18:11:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2390 [11/06/08 10:18:11:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2391 [11/06/08 10:18:11:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2392 [11/06/08 10:18:23:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
2393 [11/06/08 10:18:23:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2394 [11/06/08 10:18:23:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2395 [11/06/08 10:18:27:500]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0x80', Variation % lampe repas: 50
2396 [11/06/08 10:18:27:500]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x80', Inclinaison % lamelles store: 50
2397 [11/06/08 10:18:29:187]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0x7F', Info d'tat % inclinaison lamelles: 50
2398 [11/06/08 10:18:29:187]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0xF2', Info d'tat % position store letrique: 95
2399 [11/06/08 10:18:35:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2400 [11/06/08 10:18:35:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2401 [11/06/08 10:18:35:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x0C 0x00 0x00', Puissance Extrieur: 35.00 W
2402 [11/06/08 10:18:46:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2403 [11/06/08 10:18:46:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2404 [11/06/08 10:18:46:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2405 [11/06/08 10:18:58:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2406 [11/06/08 10:18:58:515]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2407 [11/06/08 10:18:58:515]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2408 [11/06/08 10:19:10:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDC 0x00 0x00', Puissance Hall: 110.00 W
2409 [11/06/08 10:19:10:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2410 [11/06/08 10:19:10:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2411 [11/06/08 10:19:12:250]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1D 0x0D', Luminosit: 103.44 Lux
2412 [11/06/08 10:19:22:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDC 0x00 0x00', Puissance Hall: 110.00 W
2413 [11/06/08 10:19:22:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2414 [11/06/08 10:19:22:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2415 [11/06/08 10:19:27:875]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0x80', Variation % lampe repas: 50
2416 [11/06/08 10:19:27:937]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x80', Inclinaison % lamelles store: 50
2417 [11/06/08 10:19:29:062]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2418 [11/06/08 10:19:29:125]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2419 [11/06/08 10:19:31:062]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2420 [11/06/08 10:19:31:125]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2421 [11/06/08 10:19:34:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xEE 0x00 0x00', Puissance Hall: 119.00 W
2422 [11/06/08 10:19:34:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0x1A 0xC0 0x00', Puissance Chambre: 619.00 W
2423 [11/06/08 10:19:34:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x3C 0x00 0x00', Puissance Extrieur: 47.00 W
2424 [11/06/08 10:19:46:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2425 [11/06/08 10:19:46:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2426 [11/06/08 10:19:46:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2427 [11/06/08 10:19:53:937]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
2428 [11/06/08 10:19:58:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2429 [11/06/08 10:19:58:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2430 [11/06/08 10:19:58:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2431 [11/06/08 10:20:10:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2432 [11/06/08 10:20:10:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2433 [11/06/08 10:20:10:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2434 [11/06/08 10:20:12:937]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1D 0x1F', Luminosit: 104.88 Lux
2435 [11/06/08 10:20:22:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDC 0x00 0x00', Puissance Hall: 110.00 W
2436 [11/06/08 10:20:22:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2437 [11/06/08 10:20:22:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2438 [11/06/08 10:20:28:375]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0x80', Variation % lampe repas: 50
2439 [11/06/08 10:20:28:375]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x80', Inclinaison % lamelles store: 50
2440 [11/06/08 10:20:34:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xD8 0x00 0x00', Puissance Hall: 108.00 W
2441 [11/06/08 10:20:34:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2442 [11/06/08 10:20:34:203]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2443 [11/06/08 10:20:46:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2444 [11/06/08 10:20:46:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2445 [11/06/08 10:20:46:125]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2446 [11/06/08 10:20:58:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2447 [11/06/08 10:20:58:062]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2448 [11/06/08 10:20:58:062]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2449 [11/06/08 10:21:00:625]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
2450 [11/06/08 10:21:08:562]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2451 [11/06/08 10:21:08:687]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2452 [11/06/08 10:21:09:953]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2453 [11/06/08 10:21:10:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2454 [11/06/08 10:21:10:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2455 [11/06/08 10:21:10:562]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2456 [11/06/08 10:21:10:687]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2457 [11/06/08 10:21:13:625]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1D 0x11', Luminosit: 103.76 Lux
2458 [11/06/08 10:21:21:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2459 [11/06/08 10:21:21:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2460 [11/06/08 10:21:22:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2461 [11/06/08 10:21:28:687]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0x80', Variation % lampe repas: 50
2462 [11/06/08 10:21:28:687]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x80', Inclinaison % lamelles store: 50
2463 [11/06/08 10:21:33:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDC 0x00 0x00', Puissance Hall: 110.00 W
2464 [11/06/08 10:21:33:875]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2465 [11/06/08 10:21:33:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2466 [11/06/08 10:21:45:812]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2467 [11/06/08 10:21:45:890]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2468 [11/06/08 10:21:45:890]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x10 0x00 0x00', Puissance Extrieur: 36.00 W
2469 [11/06/08 10:21:52:187]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2470 [11/06/08 10:21:52:250]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
2471 [11/06/08 10:21:57:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x4E 0x00 0x00', Puissance Hall: 206.00 W
2472 [11/06/08 10:21:57:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2473 [11/06/08 10:21:57:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x18 0x00 0x00', Puissance Extrieur: 38.00 W
2474 [11/06/08 10:22:00:937]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2475 [11/06/08 10:22:07:375]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0xBB', Luminosit: 96.88 Lux
2476 [11/06/08 10:22:09:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x4E 0x00 0x00', Puissance Hall: 206.00 W
2477 [11/06/08 10:22:09:750]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2478 [11/06/08 10:22:09:750]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x08 0x00 0x00', Puissance Extrieur: 34.00 W
2479 [11/06/08 10:22:11:437]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2480 [11/06/08 10:22:14:062]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
2481 [11/06/08 10:22:21:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x4E 0x00 0x00', Puissance Hall: 206.00 W
2482 [11/06/08 10:22:21:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2483 [11/06/08 10:22:21:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
2484 [11/06/08 10:22:29:062]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0x80', Variation % lampe repas: 50
2485 [11/06/08 10:22:29:062]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x80', Inclinaison % lamelles store: 50
2486 [11/06/08 10:22:29:187]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
2487 [11/06/08 10:22:33:687]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2488 [11/06/08 10:22:33:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2489 [11/06/08 10:22:33:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2490 [11/06/08 10:22:39:250]: GroupDataConfirmationWrite: 04/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Soire rception ON/OFF: on
2491 [11/06/08 10:22:39:312]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir chambre: on
2492 [11/06/08 10:22:39:312]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
2493 [11/06/08 10:22:41:500]: GroupDataConfirmationWrite: 04/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Soire rception ON/OFF: off
2494 [11/06/08 10:22:45:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x4F 0x00 0x00', Puissance Hall: 207.00 W
2495 [11/06/08 10:22:45:625]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xCA 0x00 0x00', Puissance Chambre: 101.00 W
2496 [11/06/08 10:22:45:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2497 [11/06/08 10:22:46:125]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2498 [11/06/08 10:22:46:187]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2499 [11/06/08 10:22:50:125]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2500 [11/06/08 10:22:50:187]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2501 [11/06/08 10:22:54:500]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2502 [11/06/08 10:22:56:937]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir chambre: off
2503 [11/06/08 10:22:57:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x4E 0x00 0x00', Puissance Hall: 206.00 W
2504 [11/06/08 10:22:57:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xCA 0x00 0x00', Puissance Chambre: 101.00 W
2505 [11/06/08 10:22:57:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
2506 [11/06/08 10:23:03:875]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2507 [11/06/08 10:23:06:312]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
2508 [11/06/08 10:23:07:875]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x94', Luminosit: 93.76 Lux
2509 [11/06/08 10:23:09:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x4D 0x00 0x00', Puissance Hall: 205.00 W
2510 [11/06/08 10:23:09:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2511 [11/06/08 10:23:09:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
2512 [11/06/08 10:23:14:000]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
2513 [11/06/08 10:23:15:250]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
2514 [11/06/08 10:23:20:375]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir hall: off
2515 [11/06/08 10:23:21:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x4D 0x00 0x00', Puissance Hall: 205.00 W
2516 [11/06/08 10:23:21:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
2517 [11/06/08 10:23:21:546]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
2518 [11/06/08 10:23:29:500]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0x80', Variation % lampe repas: 50
2519 [11/06/08 10:23:29:500]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x80', Inclinaison % lamelles store: 50
2520 [11/06/08 10:23:33:437]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDC 0x00 0x00', Puissance Hall: 110.00 W
2521 [11/06/08 10:23:33:437]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2522 [11/06/08 10:23:33:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2523 [11/06/08 10:23:45:375]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2524 [11/06/08 10:23:45:375]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2525 [11/06/08 10:23:45:437]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2526 [11/06/08 10:23:57:312]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xD8 0x00 0x00', Puissance Hall: 108.00 W
2527 [11/06/08 10:23:57:312]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2528 [11/06/08 10:23:57:375]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2529 [11/06/08 10:24:08:515]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0x9F', Luminosit: 94.64 Lux
2530 [11/06/08 10:24:09:265]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xD8 0x00 0x00', Puissance Hall: 108.00 W
2531 [11/06/08 10:24:09:328]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2532 [11/06/08 10:24:09:343]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2533 [11/06/08 10:24:21:265]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xD8 0x00 0x00', Puissance Hall: 108.00 W
2534 [11/06/08 10:24:21:328]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2535 [11/06/08 10:24:21:328]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2536 [11/06/08 10:24:23:640]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2537 [11/06/08 10:24:23:765]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2538 [11/06/08 10:24:25:640]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2539 [11/06/08 10:24:25:781]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2540 [11/06/08 10:24:29:828]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0x80', Variation % lampe repas: 50
2541 [11/06/08 10:24:29:890]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x80', Inclinaison % lamelles store: 50
2542 [11/06/08 10:24:33:265]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDC 0x00 0x00', Puissance Hall: 110.00 W
2543 [11/06/08 10:24:33:265]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2544 [11/06/08 10:24:33:328]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2545 [11/06/08 10:24:45:265]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDC 0x00 0x00', Puissance Hall: 110.00 W
2546 [11/06/08 10:24:45:265]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2547 [11/06/08 10:24:45:328]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2548 [11/06/08 10:24:57:203]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2549 [11/06/08 10:24:57:265]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2550 [11/06/08 10:24:57:328]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2551 [11/06/08 10:25:03:265]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1C 0xDD', Luminosit: 99.60 Lux
2552 [11/06/08 10:25:09:390]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDC 0x00 0x00', Puissance Hall: 110.00 W
2553 [11/06/08 10:25:09:390]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2554 [11/06/08 10:25:09:390]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2555 [11/06/08 10:25:21:203]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2556 [11/06/08 10:25:21:203]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2557 [11/06/08 10:25:21:312]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2558 [11/06/08 10:25:30:265]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0x80', Variation % lampe repas: 50
2559 [11/06/08 10:25:30:328]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x80', Inclinaison % lamelles store: 50
2560 [11/06/08 10:25:33:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Hall: 109.00 W
2561 [11/06/08 10:25:33:640]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
2562 [11/06/08 10:25:33:640]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2563 [11/06/08 10:25:42:828]: GroupDataConfirmationWrite: 06/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes hall et repas: off
2564 [11/06/08 10:25:42:890]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat  ON/OFF lampes hall et repas: off
2565 [11/06/08 10:25:42:890]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat  ON/OFF lampes hall et repas: off
2566 [11/06/08 10:25:45:140]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC6 0x00 0x00', Puissance Hall: 99.00 W
2567 [11/06/08 10:25:45:203]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
2568 [11/06/08 10:25:45:203]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2569 [11/06/08 10:25:54:265]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1D 0x1B', Luminosit: 104.56 Lux
2570 [11/06/08 10:25:57:140]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
2571 [11/06/08 10:25:57:203]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
2572 [11/06/08 10:25:57:203]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
2573 [11/06/08 10:26:01:203]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2574 [11/06/08 10:26:01:265]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2575 [11/06/08 10:26:03:203]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2576 [11/06/08 10:26:03:265]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2577 [11/06/08 10:26:09:140]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Hall: 0.00 W
2578 [11/06/08 10:26:09:140]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
2579 [11/06/08 10:26:09:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
2580 [11/06/08 10:26:21:140]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
2581 [11/06/08 10:26:21:140]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
2582 [11/06/08 10:26:21:140]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
2583 [11/06/08 10:26:30:703]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0x80', Variation % lampe repas: 50
2584 [11/06/08 10:26:30:703]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x80', Inclinaison % lamelles store: 50
2585 [11/06/08 10:26:33:078]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
2586 [11/06/08 10:26:33:156]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
2587 [11/06/08 10:26:33:171]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
2588 [11/06/08 10:26:36:515]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
2589 [11/06/08 10:26:45:078]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
2590 [11/06/08 10:26:45:078]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
2591 [11/06/08 10:26:45:140]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
2592 [11/06/08 10:26:54:890]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1D 0x4E', Luminosit: 108.64 Lux
2593 [11/06/08 10:26:57:078]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
2594 [11/06/08 10:26:57:078]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
2595 [11/06/08 10:26:57:140]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
2596 [11/06/08 10:27:05:265]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x02 0xDA', Luminosit: 7.30 Lux
2597 [11/06/08 10:27:09:015]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
2598 [11/06/08 10:27:09:093]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
2599 [11/06/08 10:27:09:093]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
2600 [11/06/08 10:27:15:328]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
2601 [11/06/08 10:27:15:328]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
2602 [11/06/08 10:27:17:015]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat % inclinaison lamelles: 0
2603 [11/06/08 10:27:17:078]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0xE5', Info d'tat % position store letrique: 90
2604 [11/06/08 10:27:21:015]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Hall: 1.00 W
2605 [11/06/08 10:27:21:093]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Chambre: 0.00 W
2606 [11/06/08 10:27:21:093]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x00 0x00 0x00 0x00', Puissance Extrieur: 0.00 W
2607 [11/06/08 10:27:21:203]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x06 0x6D', Luminosit: 16.45 Lux
2608 [11/06/08 10:27:21:453]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2609 [11/06/08 10:27:21:515]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
2610 [11/06/08 10:27:23:640]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x1D 0x88', Luminosit: 113.28 Lux
2611 [11/06/08 10:27:30:140]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
2612 [11/06/08 10:27:33:015]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xC2 0x00 0x00', Puissance Hall: 97.00 W
2613 [11/06/08 10:27:33:015]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x00 0x00 0x00', Puissance Chambre: 2.00 W
2614 [11/06/08 10:27:33:078]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
2615 [11/06/08 10:27:33:578]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0x80', Variation % lampe repas: 50
2616 [11/06/08 10:27:33:578]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x80', Inclinaison % lamelles store: 50
2617 [11/06/08 10:27:35:265]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0x7F', Info d'tat % inclinaison lamelles: 50
2618 [11/06/08 10:27:35:265]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0xF2', Info d'tat % position store letrique: 95
2619 [11/06/08 10:27:35:390]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir hall: off
2620 [11/06/08 10:27:40:703]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
2621 [11/06/08 10:27:40:765]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
2622 [11/06/08 10:27:43:062]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
2623 [11/06/08 10:27:43:078]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
2624 [11/06/08 10:27:43:593]: EIB connection terminated