0 [11/04/08 17:05:38:343]: EIB connection established
1 [11/04/08 17:06:45:859]: GroupDataConfirmationRead: 00/0003, RoutingCnt=6, PriorityLow, No Error
2 [11/04/08 17:06:45:890]: GroupDataIndicationResponse: 01.01.006, 00/0003, RoutingCnt=6, PriorityLow, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
3 [11/04/08 17:06:46:500]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
4 [11/04/08 17:06:55:859]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
5 [11/04/08 17:06:55:859]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
6 [11/04/08 17:06:55:921]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
7 [11/04/08 17:07:07:859]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
8 [11/04/08 17:07:07:859]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
9 [11/04/08 17:07:07:859]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
10 [11/04/08 17:07:10:359]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
11 [11/04/08 17:07:19:828]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x05 0x00 0x00', Puissance Hall: 133.00 W
12 [11/04/08 17:07:19:828]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
13 [11/04/08 17:07:19:906]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
14 [11/04/08 17:07:31:828]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
15 [11/04/08 17:07:31:828]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
16 [11/04/08 17:07:31:828]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
17 [11/04/08 17:07:32:765]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xFC', Luminosit: 12.76 Lux
18 [11/04/08 17:07:34:281]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
19 [11/04/08 17:07:39:593]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
20 [11/04/08 17:07:39:593]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
21 [11/04/08 17:07:43:781]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
22 [11/04/08 17:07:43:843]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
23 [11/04/08 17:07:43:843]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
24 [11/04/08 17:07:50:218]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
25 [11/04/08 17:07:50:281]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
26 [11/04/08 17:07:54:156]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
27 [11/04/08 17:07:54:218]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
28 [11/04/08 17:07:55:750]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x26 0x00 0x00', Puissance Hall: 166.00 W
29 [11/04/08 17:07:55:812]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xEC 0x20 0x00', Puissance Chambre: 1889.00 W
30 [11/04/08 17:07:55:812]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x08 0x00 0x00', Puissance Extrieur: 34.00 W
31 [11/04/08 17:08:07:734]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
32 [11/04/08 17:08:07:796]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
33 [11/04/08 17:08:07:859]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
34 [11/04/08 17:08:12:109]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
35 [11/04/08 17:08:19:734]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
36 [11/04/08 17:08:19:734]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
37 [11/04/08 17:08:19:796]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
38 [11/04/08 17:08:31:734]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
39 [11/04/08 17:08:31:734]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
40 [11/04/08 17:08:31:796]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
41 [11/04/08 17:08:33:421]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xFE', Luminosit: 12.78 Lux
42 [11/04/08 17:08:39:921]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
43 [11/04/08 17:08:39:921]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
44 [11/04/08 17:08:43:734]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
45 [11/04/08 17:08:43:734]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
46 [11/04/08 17:08:43:734]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
47 [11/04/08 17:08:44:109]: GroupDataConfirmationRead: 04/0001, RoutingCnt=6, PriorityLow, No Error
48 [11/04/08 17:08:44:171]: GroupDataIndicationResponse: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x00', Soire rception ON/OFF: off
49 [11/04/08 17:08:45:109]: GroupDataConfirmationRead: 06/0002, RoutingCnt=6, PriorityLow, No Error
50 [11/04/08 17:08:55:671]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
51 [11/04/08 17:08:55:734]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
52 [11/04/08 17:08:55:734]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
53 [11/04/08 17:08:55:859]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
54 [11/04/08 17:09:07:671]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
55 [11/04/08 17:09:07:671]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
56 [11/04/08 17:09:07:734]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
57 [11/04/08 17:09:19:671]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
58 [11/04/08 17:09:19:671]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
59 [11/04/08 17:09:19:734]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
60 [11/04/08 17:09:27:734]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
61 [11/04/08 17:09:29:734]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
62 [11/04/08 17:09:29:796]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
63 [11/04/08 17:09:31:609]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
64 [11/04/08 17:09:31:718]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
65 [11/04/08 17:09:31:734]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
66 [11/04/08 17:09:31:734]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
67 [11/04/08 17:09:31:796]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
68 [11/04/08 17:09:33:984]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xFC', Luminosit: 12.76 Lux
69 [11/04/08 17:09:40:296]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
70 [11/04/08 17:09:40:359]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
71 [11/04/08 17:09:43:609]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
72 [11/04/08 17:09:43:687]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
73 [11/04/08 17:09:43:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
74 [11/04/08 17:09:55:609]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
75 [11/04/08 17:09:55:671]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
76 [11/04/08 17:09:55:671]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
77 [11/04/08 17:10:01:671]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
78 [11/04/08 17:10:07:609]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
79 [11/04/08 17:10:07:609]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
80 [11/04/08 17:10:07:703]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
81 [11/04/08 17:10:19:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
82 [11/04/08 17:10:19:640]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
83 [11/04/08 17:10:19:640]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
84 [11/04/08 17:10:31:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
85 [11/04/08 17:10:31:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
86 [11/04/08 17:10:31:625]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
87 [11/04/08 17:10:34:625]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xFD', Luminosit: 12.77 Lux
88 [11/04/08 17:10:40:812]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
89 [11/04/08 17:10:40:812]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
90 [11/04/08 17:10:43:562]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
91 [11/04/08 17:10:43:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
92 [11/04/08 17:10:43:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
93 [11/04/08 17:10:46:062]: GroupDataConfirmationRead: 06/0002, RoutingCnt=6, PriorityLow, No Error
94 [11/04/08 17:10:49:375]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFD', Temprature chambre: 20.24 C
95 [11/04/08 17:10:55:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
96 [11/04/08 17:10:55:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
97 [11/04/08 17:10:55:578]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
98 [11/04/08 17:11:07:250]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
99 [11/04/08 17:11:07:312]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
100 [11/04/08 17:11:07:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
101 [11/04/08 17:11:07:562]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
102 [11/04/08 17:11:07:562]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
103 [11/04/08 17:11:15:250]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
104 [11/04/08 17:11:15:250]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
105 [11/04/08 17:11:19:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x13 0x00 0x00', Puissance Hall: 147.00 W
106 [11/04/08 17:11:19:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0x3B 0x00 0x00', Puissance Chambre: 748.00 W
107 [11/04/08 17:11:19:578]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x60 0x00 0x00', Puissance Extrieur: 14.00 W
108 [11/04/08 17:11:23:187]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
109 [11/04/08 17:11:27:187]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
110 [11/04/08 17:11:31:125]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
111 [11/04/08 17:11:31:500]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
112 [11/04/08 17:11:31:500]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
113 [11/04/08 17:11:31:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
114 [11/04/08 17:11:35:312]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xFA', Luminosit: 12.74 Lux
115 [11/04/08 17:11:41:125]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x04', Temprature chambre: 20.80 C
116 [11/04/08 17:11:41:125]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
117 [11/04/08 17:11:41:187]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
118 [11/04/08 17:11:42:250]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
119 [11/04/08 17:11:42:250]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
120 [11/04/08 17:11:42:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
121 [11/04/08 17:11:54:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
122 [11/04/08 17:11:54:187]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
123 [11/04/08 17:11:54:250]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
124 [11/04/08 17:12:06:125]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
125 [11/04/08 17:12:06:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
126 [11/04/08 17:12:06:187]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
127 [11/04/08 17:12:14:937]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
128 [11/04/08 17:12:18:062]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
129 [11/04/08 17:12:18:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
130 [11/04/08 17:12:18:125]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
131 [11/04/08 17:12:30:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
132 [11/04/08 17:12:30:078]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
133 [11/04/08 17:12:30:078]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
134 [11/04/08 17:12:36:000]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xF0', Luminosit: 12.64 Lux
135 [11/04/08 17:12:41:500]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
136 [11/04/08 17:12:41:500]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
137 [11/04/08 17:12:42:000]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
138 [11/04/08 17:12:42:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
139 [11/04/08 17:12:42:062]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
140 [11/04/08 17:12:42:828]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
141 [11/04/08 17:12:47:062]: GroupDataConfirmationRead: 06/0002, RoutingCnt=6, PriorityLow, No Error
142 [11/04/08 17:12:53:937]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
143 [11/04/08 17:12:54:000]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
144 [11/04/08 17:12:54:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
145 [11/04/08 17:13:05:875]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
146 [11/04/08 17:13:05:937]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
147 [11/04/08 17:13:05:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
148 [11/04/08 17:13:12:640]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
149 [11/04/08 17:13:12:750]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
150 [11/04/08 17:13:12:765]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
151 [11/04/08 17:13:17:828]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
152 [11/04/08 17:13:17:890]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
153 [11/04/08 17:13:17:890]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
154 [11/04/08 17:13:22:953]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
155 [11/04/08 17:13:29:828]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
156 [11/04/08 17:13:29:828]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
157 [11/04/08 17:13:29:890]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
158 [11/04/08 17:13:36:656]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xE1', Luminosit: 12.49 Lux
159 [11/04/08 17:13:41:765]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
160 [11/04/08 17:13:41:765]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
161 [11/04/08 17:13:41:843]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
162 [11/04/08 17:13:42:015]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
163 [11/04/08 17:13:42:015]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
164 [11/04/08 17:13:44:515]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
165 [11/04/08 17:13:53:703]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
166 [11/04/08 17:13:53:796]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
167 [11/04/08 17:13:53:796]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
168 [11/04/08 17:14:05:890]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
169 [11/04/08 17:14:06:093]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
170 [11/04/08 17:14:06:156]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
171 [11/04/08 17:14:17:640]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
172 [11/04/08 17:14:17:640]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
173 [11/04/08 17:14:17:718]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
174 [11/04/08 17:14:18:328]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFD', Temprature chambre: 20.24 C
175 [11/04/08 17:14:24:328]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
176 [11/04/08 17:14:24:390]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
177 [11/04/08 17:14:29:578]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x26 0x00 0x00', Puissance Hall: 166.00 W
178 [11/04/08 17:14:29:578]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xEB 0xE0 0x00', Puissance Chambre: 1887.00 W
179 [11/04/08 17:14:29:656]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x08 0x00 0x00', Puissance Extrieur: 34.00 W
180 [11/04/08 17:14:30:328]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
181 [11/04/08 17:14:30:328]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
182 [11/04/08 17:14:37:328]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xDD', Luminosit: 12.45 Lux
183 [11/04/08 17:14:38:265]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
184 [11/04/08 17:14:41:515]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
185 [11/04/08 17:14:41:578]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
186 [11/04/08 17:14:41:578]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
187 [11/04/08 17:14:42:265]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
188 [11/04/08 17:14:42:328]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
189 [11/04/08 17:14:42:390]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
190 [11/04/08 17:14:52:203]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
191 [11/04/08 17:14:53:515]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
192 [11/04/08 17:14:53:515]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
193 [11/04/08 17:14:53:515]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
194 [11/04/08 17:15:05:453]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
195 [11/04/08 17:15:05:453]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
196 [11/04/08 17:15:05:515]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
197 [11/04/08 17:15:17:390]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
198 [11/04/08 17:15:17:390]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
199 [11/04/08 17:15:17:484]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
200 [11/04/08 17:15:29:328]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
201 [11/04/08 17:15:29:406]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
202 [11/04/08 17:15:29:406]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
203 [11/04/08 17:15:38:015]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xD5', Luminosit: 12.37 Lux
204 [11/04/08 17:15:41:328]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
205 [11/04/08 17:15:41:328]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
206 [11/04/08 17:15:41:390]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
207 [11/04/08 17:15:42:703]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
208 [11/04/08 17:15:42:765]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
209 [11/04/08 17:15:47:953]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
210 [11/04/08 17:15:53:265]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
211 [11/04/08 17:15:53:265]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
212 [11/04/08 17:15:53:328]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
213 [11/04/08 17:16:01:828]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
214 [11/04/08 17:16:01:953]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
215 [11/04/08 17:16:05:203]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x1E 0x00 0x00', Puissance Hall: 158.00 W
216 [11/04/08 17:16:05:281]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xAB 0xE0 0x00', Puissance Chambre: 1375.00 W
217 [11/04/08 17:16:05:281]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0xC8 0x00 0x00', Puissance Extrieur: 25.00 W
218 [11/04/08 17:16:05:828]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
219 [11/04/08 17:16:05:890]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
220 [11/04/08 17:16:17:140]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
221 [11/04/08 17:16:17:203]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
222 [11/04/08 17:16:17:203]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
223 [11/04/08 17:16:21:765]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
224 [11/04/08 17:16:29:140]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
225 [11/04/08 17:16:29:140]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
226 [11/04/08 17:16:29:234]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
227 [11/04/08 17:16:38:640]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xCE', Luminosit: 12.30 Lux
228 [11/04/08 17:16:41:078]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
229 [11/04/08 17:16:41:078]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
230 [11/04/08 17:16:41:140]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
231 [11/04/08 17:16:43:203]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
232 [11/04/08 17:16:43:203]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
233 [11/04/08 17:16:44:265]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
234 [11/04/08 17:16:53:015]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
235 [11/04/08 17:16:53:078]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
236 [11/04/08 17:16:53:078]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
237 [11/04/08 17:17:05:015]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
238 [11/04/08 17:17:05:078]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
239 [11/04/08 17:17:05:078]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
240 [11/04/08 17:17:17:015]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
241 [11/04/08 17:17:17:015]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
242 [11/04/08 17:17:17:078]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
243 [11/04/08 17:17:29:015]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
244 [11/04/08 17:17:29:015]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
245 [11/04/08 17:17:29:078]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
246 [11/04/08 17:17:29:453]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
247 [11/04/08 17:17:39:437]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xD1', Luminosit: 12.33 Lux
248 [11/04/08 17:17:39:468]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
249 [11/04/08 17:17:39:531]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
250 [11/04/08 17:17:41:187]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
251 [11/04/08 17:17:41:218]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
252 [11/04/08 17:17:41:500]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
253 [11/04/08 17:17:43:625]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
254 [11/04/08 17:17:43:875]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
255 [11/04/08 17:17:45:531]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
256 [11/04/08 17:17:45:531]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
257 [11/04/08 17:17:53:156]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
258 [11/04/08 17:17:53:156]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
259 [11/04/08 17:17:53:156]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
260 [11/04/08 17:17:57:343]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
261 [11/04/08 17:18:01:281]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
262 [11/04/08 17:18:05:015]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
263 [11/04/08 17:18:05:015]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
264 [11/04/08 17:18:05:015]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
265 [11/04/08 17:18:11:218]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x04', Temprature chambre: 20.80 C
266 [11/04/08 17:18:16:968]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
267 [11/04/08 17:18:16:968]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
268 [11/04/08 17:18:16:968]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
269 [11/04/08 17:18:28:906]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
270 [11/04/08 17:18:28:968]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
271 [11/04/08 17:18:28:968]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
272 [11/04/08 17:18:39:843]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xCC', Luminosit: 12.28 Lux
273 [11/04/08 17:18:40:906]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
274 [11/04/08 17:18:40:906]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
275 [11/04/08 17:18:41:000]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
276 [11/04/08 17:18:43:843]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
277 [11/04/08 17:18:43:906]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
278 [11/04/08 17:18:52:906]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
279 [11/04/08 17:18:52:906]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
280 [11/04/08 17:18:52:906]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
281 [11/04/08 17:18:59:031]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
282 [11/04/08 17:19:04:843]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
283 [11/04/08 17:19:04:906]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
284 [11/04/08 17:19:04:906]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
285 [11/04/08 17:19:16:843]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
286 [11/04/08 17:19:16:906]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
287 [11/04/08 17:19:16:906]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
288 [11/04/08 17:19:28:843]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
289 [11/04/08 17:19:28:843]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
290 [11/04/08 17:19:28:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
291 [11/04/08 17:19:32:843]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
292 [11/04/08 17:19:40:468]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xC8', Luminosit: 12.24 Lux
293 [11/04/08 17:19:40:843]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
294 [11/04/08 17:19:40:843]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
295 [11/04/08 17:19:40:843]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
296 [11/04/08 17:19:40:843]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
297 [11/04/08 17:19:40:937]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
298 [11/04/08 17:19:44:343]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
299 [11/04/08 17:19:44:406]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
300 [11/04/08 17:19:52:781]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
301 [11/04/08 17:19:52:843]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
302 [11/04/08 17:19:52:843]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
303 [11/04/08 17:20:00:718]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
304 [11/04/08 17:20:04:781]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
305 [11/04/08 17:20:04:781]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
306 [11/04/08 17:20:04:859]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
307 [11/04/08 17:20:05:593]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
308 [11/04/08 17:20:16:781]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
309 [11/04/08 17:20:16:781]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
310 [11/04/08 17:20:16:843]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
311 [11/04/08 17:20:28:718]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
312 [11/04/08 17:20:28:781]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
313 [11/04/08 17:20:28:843]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
314 [11/04/08 17:20:38:531]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
315 [11/04/08 17:20:40:718]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
316 [11/04/08 17:20:40:781]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
317 [11/04/08 17:20:40:781]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
318 [11/04/08 17:20:41:156]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xC5', Luminosit: 12.21 Lux
319 [11/04/08 17:20:44:718]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
320 [11/04/08 17:20:44:718]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
321 [11/04/08 17:20:52:718]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
322 [11/04/08 17:20:52:718]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
323 [11/04/08 17:20:52:781]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
324 [11/04/08 17:20:54:656]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
325 [11/04/08 17:20:54:671]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
326 [11/04/08 17:21:02:406]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
327 [11/04/08 17:21:02:531]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
328 [11/04/08 17:21:04:718]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x25 0x00 0x00', Puissance Hall: 165.00 W
329 [11/04/08 17:21:04:718]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xEB 0x00 0x00', Puissance Chambre: 1880.00 W
330 [11/04/08 17:21:04:781]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x04 0x00 0x00', Puissance Extrieur: 33.00 W
331 [11/04/08 17:21:12:406]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
332 [11/04/08 17:21:16:343]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
333 [11/04/08 17:21:16:656]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x04 0x00 0x00', Puissance Hall: 132.00 W
334 [11/04/08 17:21:16:718]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
335 [11/04/08 17:21:16:718]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
336 [11/04/08 17:21:22:343]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x04', Temprature chambre: 20.80 C
337 [11/04/08 17:21:28:656]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x05 0x00 0x00', Puissance Hall: 133.00 W
338 [11/04/08 17:21:28:718]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
339 [11/04/08 17:21:28:718]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
340 [11/04/08 17:21:30:281]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x05', Temprature chambre: 20.88 C
341 [11/04/08 17:21:40:656]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x04 0x00 0x00', Puissance Hall: 132.00 W
342 [11/04/08 17:21:40:656]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
343 [11/04/08 17:21:40:718]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
344 [11/04/08 17:21:41:781]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xBF', Luminosit: 12.15 Lux
345 [11/04/08 17:21:45:031]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
346 [11/04/08 17:21:45:093]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
347 [11/04/08 17:21:52:656]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x05 0x00 0x00', Puissance Hall: 133.00 W
348 [11/04/08 17:21:52:656]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
349 [11/04/08 17:21:52:718]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
350 [11/04/08 17:22:04:593]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x05 0x00 0x00', Puissance Hall: 133.00 W
351 [11/04/08 17:22:04:656]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
352 [11/04/08 17:22:04:656]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
353 [11/04/08 17:22:14:156]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x04', Temprature chambre: 20.80 C
354 [11/04/08 17:22:16:593]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
355 [11/04/08 17:22:16:656]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
356 [11/04/08 17:22:16:687]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
357 [11/04/08 17:22:28:593]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x05 0x00 0x00', Puissance Hall: 133.00 W
358 [11/04/08 17:22:28:593]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
359 [11/04/08 17:22:28:656]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
360 [11/04/08 17:22:40:593]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
361 [11/04/08 17:22:40:593]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
362 [11/04/08 17:22:40:593]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
363 [11/04/08 17:22:41:968]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x02', Temprature chambre: 20.64 C
364 [11/04/08 17:22:42:468]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xBB', Luminosit: 12.11 Lux
365 [11/04/08 17:22:45:531]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
366 [11/04/08 17:22:45:593]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
367 [11/04/08 17:22:52:531]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
368 [11/04/08 17:22:52:593]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
369 [11/04/08 17:22:52:593]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
370 [11/04/08 17:22:59:843]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
371 [11/04/08 17:22:59:906]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
372 [11/04/08 17:23:04:531]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
373 [11/04/08 17:23:04:593]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
374 [11/04/08 17:23:04:609]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
375 [11/04/08 17:23:11:781]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
376 [11/04/08 17:23:16:531]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
377 [11/04/08 17:23:16:531]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
378 [11/04/08 17:23:16:593]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
379 [11/04/08 17:23:26:906]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
380 [11/04/08 17:23:28:531]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
381 [11/04/08 17:23:28:531]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
382 [11/04/08 17:23:28:531]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
383 [11/04/08 17:23:39:656]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
384 [11/04/08 17:23:40:468]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
385 [11/04/08 17:23:40:531]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
386 [11/04/08 17:23:40:531]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
387 [11/04/08 17:23:43:093]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xC1', Luminosit: 12.17 Lux
388 [11/04/08 17:23:45:906]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
389 [11/04/08 17:23:45:906]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
390 [11/04/08 17:23:52:468]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
391 [11/04/08 17:23:52:468]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
392 [11/04/08 17:23:52:531]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
393 [11/04/08 17:24:04:468]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x05 0x00 0x00', Puissance Hall: 133.00 W
394 [11/04/08 17:24:04:468]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
395 [11/04/08 17:24:04:531]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
396 [11/04/08 17:24:11:531]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
397 [11/04/08 17:24:11:593]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
398 [11/04/08 17:24:13:531]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
399 [11/04/08 17:24:15:531]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
400 [11/04/08 17:24:15:593]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
401 [11/04/08 17:24:16:468]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x26 0x00 0x00', Puissance Hall: 166.00 W
402 [11/04/08 17:24:16:468]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x44 0xE2 0x60 0x00', Puissance Chambre: 1811.00 W
403 [11/04/08 17:24:16:468]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x42 0x00 0x00 0x00', Puissance Extrieur: 32.00 W
404 [11/04/08 17:24:27:468]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
405 [11/04/08 17:24:28:406]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x05 0x00 0x00', Puissance Hall: 133.00 W
406 [11/04/08 17:24:28:468]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
407 [11/04/08 17:24:28:468]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
408 [11/04/08 17:24:37:406]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
409 [11/04/08 17:24:40:406]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
410 [11/04/08 17:24:40:406]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
411 [11/04/08 17:24:40:468]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
412 [11/04/08 17:24:43:843]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xC1', Luminosit: 12.17 Lux
413 [11/04/08 17:24:46:281]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
414 [11/04/08 17:24:46:281]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
415 [11/04/08 17:24:52:406]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x05 0x00 0x00', Puissance Hall: 133.00 W
416 [11/04/08 17:24:52:406]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
417 [11/04/08 17:24:52:484]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
418 [11/04/08 17:25:03:171]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
419 [11/04/08 17:25:03:171]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
420 [11/04/08 17:25:03:218]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
421 [11/04/08 17:25:15:093]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x05 0x00 0x00', Puissance Hall: 133.00 W
422 [11/04/08 17:25:15:156]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Chambre: 3.00 W
423 [11/04/08 17:25:15:156]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
424 [11/04/08 17:25:19:218]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
425 [11/04/08 17:25:25:968]: GroupDataIndicationWrite: 01.01.010, 06/0005, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampe chambre: on
426 [11/04/08 17:25:25:968]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampe chambre: on
427 [11/04/08 17:25:26:406]: GroupDataIndicationWrite: 01.01.010, 06/0004, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir chambre: on
428 [11/04/08 17:25:26:531]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir chambre: on
429 [11/04/08 17:25:26:718]: GroupDataIndicationWrite: 01.01.010, 06/0006, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes lit: on
430 [11/04/08 17:25:26:781]: GroupDataIndicationWrite: 01.01.002, 06/0206, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes lit: on
431 [11/04/08 17:25:27:031]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x06 0x00 0x00', Puissance Hall: 134.00 W
432 [11/04/08 17:25:27:109]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Chambre: 4.00 W
433 [11/04/08 17:25:27:109]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x3F 0x80 0x00 0x00', Puissance Extrieur: 1.00 W
434 [11/04/08 17:25:29:531]: GroupDataIndicationWrite: 01.01.010, 06/0005, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampe chambre: on
435 [11/04/08 17:25:35:031]: GroupDataIndicationWrite: 01.01.010, 06/0005, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampe chambre: off
436 [11/04/08 17:25:35:093]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampe chambre: off
437 [11/04/08 17:25:35:593]: GroupDataIndicationWrite: 01.01.010, 06/0006, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes lit: off
438 [11/04/08 17:25:35:656]: GroupDataIndicationWrite: 01.01.002, 06/0206, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes lit: off
439 [11/04/08 17:25:38:968]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x08 0x00 0x00', Puissance Hall: 136.00 W
440 [11/04/08 17:25:39:031]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xC8 0x00 0x00', Puissance Chambre: 100.00 W
441 [11/04/08 17:25:39:031]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
442 [11/04/08 17:25:41:781]: GroupDataIndicationWrite: 01.01.005, 04/0002, RoutingCnt=6, PriorityLow, Data='0x01', Mode femme de mnage ON/OFF: on
443 [11/04/08 17:25:41:843]: GroupDataIndicationWrite: 01.01.003, 09/0203, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Gche lectrique: on
444 [11/04/08 17:25:41:843]: GroupDataIndicationWrite: 01.01.002, 06/0206, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes lit: on
445 [11/04/08 17:25:41:843]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampe chambre: on
446 [11/04/08 17:25:44:468]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xBF', Luminosit: 12.15 Lux
447 [11/04/08 17:25:46:593]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
448 [11/04/08 17:25:46:656]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
449 [11/04/08 17:25:48:093]: GroupDataIndicationWrite: 01.01.005, 04/0002, RoutingCnt=6, PriorityLow, Data='0x00', Mode femme de mnage ON/OFF: off
450 [11/04/08 17:25:48:093]: GroupDataIndicationWrite: 01.01.003, 09/0203, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Gche lectrique: off
451 [11/04/08 17:25:48:156]: GroupDataIndicationWrite: 01.01.002, 06/0206, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes lit: off
452 [11/04/08 17:25:48:156]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampe chambre: off
453 [11/04/08 17:25:50:906]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x07 0x00 0x00', Puissance Hall: 135.00 W
454 [11/04/08 17:25:50:968]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xD4 0x00 0x00', Puissance Chambre: 106.00 W
455 [11/04/08 17:25:50:968]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
456 [11/04/08 17:25:51:093]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
457 [11/04/08 17:25:51:093]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
458 [11/04/08 17:25:52:343]: GroupDataIndicationWrite: 01.01.005, 04/0002, RoutingCnt=6, PriorityLow, Data='0x01', Mode femme de mnage ON/OFF: on
459 [11/04/08 17:25:52:406]: GroupDataIndicationWrite: 01.01.003, 09/0203, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Gche lectrique: on
460 [11/04/08 17:25:52:406]: GroupDataIndicationWrite: 01.01.002, 06/0206, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes lit: on
461 [11/04/08 17:25:52:406]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampe chambre: on
462 [11/04/08 17:25:55:031]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
463 [11/04/08 17:25:55:093]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
464 [11/04/08 17:25:59:843]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
465 [11/04/08 17:25:59:906]: GroupDataIndicationWrite: 01.01.002, 06/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir hall: on
466 [11/04/08 17:26:02:906]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x42 0x00 0x00', Puissance Hall: 194.00 W
467 [11/04/08 17:26:02:906]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE2 0x00 0x00', Puissance Chambre: 113.00 W
468 [11/04/08 17:26:02:968]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
469 [11/04/08 17:26:08:593]: GroupDataIndicationWrite: 01.01.012, 06/0002, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes couloir hall: on
470 [11/04/08 17:26:10:718]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', Sonnerie ON/OFF: on
471 [11/04/08 17:26:10:718]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
472 [11/04/08 17:26:10:906]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', Sonnerie ON/OFF: off
473 [11/04/08 17:26:10:968]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
474 [11/04/08 17:26:10:968]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
475 [11/04/08 17:26:11:406]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', Sonnerie ON/OFF: on
476 [11/04/08 17:26:11:468]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
477 [11/04/08 17:26:12:156]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', Sonnerie ON/OFF: off
478 [11/04/08 17:26:12:218]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
479 [11/04/08 17:26:12:906]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x01', Soire rception ON/OFF: on
480 [11/04/08 17:26:13:593]: GroupDataIndicationWrite: 01.01.011, 04/0001, RoutingCnt=6, PriorityLow, Data='0x01', Soire rception ON/OFF: on
481 [11/04/08 17:26:14:218]: GroupDataIndicationWrite: 01.01.011, 09/0002, RoutingCnt=6, PriorityLow, Data='0x01', Ventouse lectromagntique ON/OFF: on
482 [11/04/08 17:26:14:218]: GroupDataIndicationWrite: 01.01.003, 09/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Ventouse lectromagntique: on
483 [11/04/08 17:26:14:843]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x6E 0x00 0x00', Puissance Hall: 238.00 W
484 [11/04/08 17:26:14:906]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE4 0x00 0x00', Puissance Chambre: 114.00 W
485 [11/04/08 17:26:14:906]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
486 [11/04/08 17:26:18:656]: GroupDataIndicationWrite: 01.01.011, 06/0001, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes hall et repas: on
487 [11/04/08 17:26:19:718]: GroupDataIndicationWrite: 01.01.011, 06/0001, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes hall et repas: on
488 [11/04/08 17:26:20:375]: GroupDataIndicationWrite: 01.01.011, 13/0002, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison/Stop store: off
489 [11/04/08 17:26:21:156]: GroupDataIndicationWrite: 01.01.011, 13/0001, RoutingCnt=6, PriorityLow, Data='0x01', Monter/Descendre Store: on
490 [11/04/08 17:26:22:218]: GroupDataConfirmationRead: 06/0801, RoutingCnt=6, PriorityLow, No Error
491 [11/04/08 17:26:22:218]: GroupDataIndicationResponse: 01.01.007, 06/0801, RoutingCnt=6, PriorityLow, Data='0xFF', Info d'tat variation % lampe repas: 100
492 [11/04/08 17:26:22:718]: GroupDataConfirmationRead: 07/0002, RoutingCnt=6, PriorityLow, No Error
493 [11/04/08 17:26:22:718]: GroupDataIndicationResponse: 01.01.004, 07/0002, RoutingCnt=6, PriorityLow, Data='0x00', Dfaut vent ON/OFF: off
494 [11/04/08 17:26:23:218]: GroupDataConfirmationRead: 07/0003, RoutingCnt=6, PriorityLow, No Error
495 [11/04/08 17:26:23:218]: GroupDataIndicationResponse: 01.01.002, 06/0001, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes hall et repas: on
496 [11/04/08 17:26:23:718]: GroupDataConfirmationRead: 13/0801, RoutingCnt=6, PriorityLow, No Error
497 [11/04/08 17:26:23:718]: GroupDataIndicationResponse: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0x35', Info d'tat % position store letrique: 21
498 [11/04/08 17:26:24:218]: GroupDataConfirmationRead: 06/0201, RoutingCnt=6, PriorityLow, No Error
499 [11/04/08 17:26:24:218]: GroupDataIndicationResponse: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat  ON/OFF lampes hall et repas: on
500 [11/04/08 17:26:24:718]: GroupDataConfirmationRead: 06/0203, RoutingCnt=6, PriorityLow, No Error
501 [11/04/08 17:26:24:718]: GroupDataIndicationResponse: 01.01.002, 06/0203, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampe SAS: off
502 [11/04/08 17:26:26:218]: GroupDataConfirmationWrite: 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Sonnerie ON/OFF: on
503 [11/04/08 17:26:26:281]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
504 [11/04/08 17:26:26:781]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0xA4 0x80 0x00', Puissance Hall: 329.00 W
505 [11/04/08 17:26:26:843]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xEC 0x00 0x00', Puissance Chambre: 118.00 W
506 [11/04/08 17:26:26:843]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
507 [11/04/08 17:26:27:156]: GroupDataConfirmationWrite: 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Sonnerie ON/OFF: off
508 [11/04/08 17:26:27:218]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
509 [11/04/08 17:26:27:593]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', Sonnerie ON/OFF: on
510 [11/04/08 17:26:27:656]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
511 [11/04/08 17:26:28:531]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', Sonnerie ON/OFF: off
512 [11/04/08 17:26:28:593]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
513 [11/04/08 17:26:29:281]: GroupDataConfirmationWrite: 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Sonnerie ON/OFF: on
514 [11/04/08 17:26:29:343]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
515 [11/04/08 17:26:29:406]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', Sonnerie ON/OFF: on
516 [11/04/08 17:26:29:656]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', Sonnerie ON/OFF: off
517 [11/04/08 17:26:29:656]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
518 [11/04/08 17:26:30:093]: GroupDataConfirmationWrite: 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Sonnerie ON/OFF: on
519 [11/04/08 17:26:30:156]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
520 [11/04/08 17:26:31:343]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', Sonnerie ON/OFF: on
521 [11/04/08 17:26:31:406]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', Sonnerie ON/OFF: off
522 [11/04/08 17:26:31:468]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
523 [11/04/08 17:26:32:156]: GroupDataIndicationWrite: 01.01.011, 13/0001, RoutingCnt=6, PriorityLow, Data='0x00', Monter/Descendre Store: off
524 [11/04/08 17:26:32:156]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0xFF', Info d'tat % inclinaison lamelles: 100
525 [11/04/08 17:26:32:218]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0xFF', Info d'tat % position store letrique: 100
526 [11/04/08 17:26:37:281]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', Sonnerie ON/OFF: on
527 [11/04/08 17:26:37:343]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
528 [11/04/08 17:26:37:531]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', Sonnerie ON/OFF: off
529 [11/04/08 17:26:37:593]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
530 [11/04/08 17:26:37:718]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', Sonnerie ON/OFF: on
531 [11/04/08 17:26:37:718]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
532 [11/04/08 17:26:37:781]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', Sonnerie ON/OFF: off
533 [11/04/08 17:26:37:843]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
534 [11/04/08 17:26:38:031]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', Sonnerie ON/OFF: on
535 [11/04/08 17:26:38:093]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
536 [11/04/08 17:26:38:656]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', Sonnerie ON/OFF: off
537 [11/04/08 17:26:38:656]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
538 [11/04/08 17:26:38:781]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0xA3 0x80 0x00', Puissance Hall: 327.00 W
539 [11/04/08 17:26:38:781]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE6 0x00 0x00', Puissance Chambre: 115.00 W
540 [11/04/08 17:26:38:781]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', Sonnerie ON/OFF: on
541 [11/04/08 17:26:38:843]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xA0 0x00 0x00', Puissance Extrieur: 5.00 W
542 [11/04/08 17:26:38:843]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
543 [11/04/08 17:26:38:968]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', Sonnerie ON/OFF: off
544 [11/04/08 17:26:39:031]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
545 [11/04/08 17:26:39:218]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x01', Sonnerie ON/OFF: on
546 [11/04/08 17:26:39:281]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Sonnerie: on
547 [11/04/08 17:26:39:968]: GroupDataConfirmationWrite: 13/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Monter/Descendre Store: off
548 [11/04/08 17:26:42:531]: GroupDataIndicationWrite: 01.01.011, 09/0001, RoutingCnt=6, PriorityLow, Data='0x00', Sonnerie ON/OFF: off
549 [11/04/08 17:26:42:531]: GroupDataIndicationWrite: 01.01.002, 09/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Sonnerie: off
550 [11/04/08 17:26:43:343]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat % inclinaison lamelles: 0
551 [11/04/08 17:26:43:343]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat % position store letrique: 0
552 [11/04/08 17:26:43:656]: GroupDataIndicationWrite: 01.01.011, 09/0002, RoutingCnt=6, PriorityLow, Data='0x01', Ventouse lectromagntique ON/OFF: on
553 [11/04/08 17:26:43:781]: GroupDataConfirmationWrite: 13/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Monter/Descendre Store: off
554 [11/04/08 17:26:45:156]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xD0', Luminosit: 12.32 Lux
555 [11/04/08 17:26:46:531]: GroupDataIndicationWrite: 01.01.011, 06/0001, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes hall et repas: on
556 [11/04/08 17:26:47:093]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
557 [11/04/08 17:26:47:093]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
558 [11/04/08 17:26:47:343]: GroupDataIndicationWrite: 01.01.011, 09/0002, RoutingCnt=6, PriorityLow, Data='0x01', Ventouse lectromagntique ON/OFF: on
559 [11/04/08 17:26:48:218]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x00', Scnario nuit ON/OFF: off
560 [11/04/08 17:26:50:093]: GroupDataIndicationWrite: 01.01.011, 09/0002, RoutingCnt=6, PriorityLow, Data='0x01', Ventouse lectromagntique ON/OFF: on
561 [11/04/08 17:26:50:531]: GroupDataConfirmationWrite: 09/0002, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Ventouse lectromagntique ON/OFF: off
562 [11/04/08 17:26:50:531]: GroupDataIndicationWrite: 01.01.003, 09/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Ventouse lectromagntique: off
563 [11/04/08 17:26:50:718]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x68 0x00 0x00', Puissance Hall: 232.00 W
564 [11/04/08 17:26:50:718]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xDC 0x00 0x00', Puissance Chambre: 110.00 W
565 [11/04/08 17:26:50:781]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
566 [11/04/08 17:26:52:531]: GroupDataIndicationWrite: 01.01.011, 09/0002, RoutingCnt=6, PriorityLow, Data='0x01', Ventouse lectromagntique ON/OFF: on
567 [11/04/08 17:26:52:531]: GroupDataIndicationWrite: 01.01.003, 09/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Ventouse lectromagntique: on
568 [11/04/08 17:26:52:593]: GroupDataConfirmationWrite: 09/0002, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Ventouse lectromagntique ON/OFF: on
569 [11/04/08 17:26:55:656]: GroupDataIndicationWrite: 01.01.011, 09/0002, RoutingCnt=6, PriorityLow, Data='0x01', Ventouse lectromagntique ON/OFF: on
570 [11/04/08 17:26:57:593]: GroupDataConfirmationWrite: 06/0001, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes hall et repas: off
571 [11/04/08 17:26:57:656]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat  ON/OFF lampes hall et repas: off
572 [11/04/08 17:26:57:656]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat  ON/OFF lampes hall et repas: off
573 [11/04/08 17:26:57:843]: GroupDataIndicationWrite: 01.01.011, 09/0002, RoutingCnt=6, PriorityLow, Data='0x01', Ventouse lectromagntique ON/OFF: on
574 [11/04/08 17:26:59:343]: GroupDataIndicationWrite: 01.01.011, 06/0001, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes hall et repas: on
575 [11/04/08 17:26:59:406]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat  ON/OFF lampes hall et repas: on
576 [11/04/08 17:26:59:406]: GroupDataIndicationWrite: 01.01.002, 06/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat  ON/OFF lampes hall et repas: on
577 [11/04/08 17:27:00:468]: GroupDataIndicationWrite: 01.01.011, 09/0002, RoutingCnt=6, PriorityLow, Data='0x01', Ventouse lectromagntique ON/OFF: on
578 [11/04/08 17:27:02:656]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x42 0xEC 0x00 0x00', Puissance Hall: 118.00 W
579 [11/04/08 17:27:02:718]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Chambre: 109.00 W
580 [11/04/08 17:27:02:718]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xE0 0x00 0x00', Puissance Extrieur: 7.00 W
581 [11/04/08 17:27:05:843]: GroupDataIndicationWrite: 01.01.011, 09/0002, RoutingCnt=6, PriorityLow, Data='0x00', Ventouse lectromagntique ON/OFF: off
582 [11/04/08 17:27:05:906]: GroupDataIndicationWrite: 01.01.003, 09/0202, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF Ventouse lectromagntique: off
583 [11/04/08 17:27:08:906]: GroupDataIndicationWrite: 01.01.011, 09/0002, RoutingCnt=6, PriorityLow, Data='0x01', Ventouse lectromagntique ON/OFF: on
584 [11/04/08 17:27:08:906]: GroupDataIndicationWrite: 01.01.003, 09/0202, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF Ventouse lectromagntique: on
585 [11/04/08 17:27:10:718]: GroupDataIndicationWrite: 01.01.010, 06/0004, RoutingCnt=6, PriorityLow, Data='0x00', Eclairage ON/OFF lampes couloir chambre: off
586 [11/04/08 17:27:11:156]: GroupDataIndicationWrite: 01.01.011, 09/0002, RoutingCnt=6, PriorityLow, Data='0x01', Ventouse lectromagntique ON/OFF: on
587 [11/04/08 17:27:12:031]: GroupDataIndicationWrite: 01.01.011, 06/0001, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes hall et repas: on
588 [11/04/08 17:27:12:718]: GroupDataIndicationWrite: 01.01.011, 09/0002, RoutingCnt=6, PriorityLow, Data='0x01', Ventouse lectromagntique ON/OFF: on
589 [11/04/08 17:27:14:656]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x11 0x00 0x00', Puissance Hall: 145.00 W
590 [11/04/08 17:27:14:656]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xDA 0x00 0x00', Puissance Chambre: 109.00 W
591 [11/04/08 17:27:14:656]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x00 0x00 0x00', Puissance Extrieur: 8.00 W
592 [11/04/08 17:27:16:406]: GroupDataConfirmationWrite: 13/0001, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Monter/Descendre Store: on
593 [11/04/08 17:27:26:593]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x7C 0x00 0x00', Puissance Hall: 252.00 W
594 [11/04/08 17:27:26:656]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xE0 0x00 0x00', Puissance Chambre: 112.00 W
595 [11/04/08 17:27:26:656]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x10 0x00 0x00', Puissance Extrieur: 9.00 W
596 [11/04/08 17:27:26:843]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir chambre: off
597 [11/04/08 17:27:28:593]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x01', Chauffer ON/OFF: on
598 [11/04/08 17:27:28:656]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
599 [11/04/08 17:27:28:656]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat Chauffage ON/OFF: on
600 [11/04/08 17:27:30:281]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0x7F', Info d'tat % inclinaison lamelles: 50
601 [11/04/08 17:27:30:281]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0xF2', Info d'tat % position store letrique: 95
602 [11/04/08 17:27:30:828]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
603 [11/04/08 17:27:31:015]: GroupDataIndicationWrite: 01.01.002, 03/0201, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat Chauffage ON/OFF: off
604 [11/04/08 17:27:38:781]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x0F 0x00 0x00', Puissance Hall: 143.00 W
605 [11/04/08 17:27:38:890]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x40 0x00 0x00', Puissance Chambre: 12.00 W
606 [11/04/08 17:27:39:171]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xE0 0x00 0x00', Puissance Extrieur: 7.00 W
607 [11/04/08 17:27:45:718]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0x9D', Luminosit: 11.81 Lux
608 [11/04/08 17:27:47:468]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
609 [11/04/08 17:27:47:531]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
610 [11/04/08 17:27:49:156]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat % inclinaison lamelles: 0
611 [11/04/08 17:27:49:218]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0xE5', Info d'tat % position store letrique: 90
612 [11/04/08 17:27:50:468]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x2A 0x00 0x00', Puissance Hall: 170.00 W
613 [11/04/08 17:27:50:531]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x00 0x00 0x00', Puissance Chambre: 8.00 W
614 [11/04/08 17:27:50:531]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xE0 0x00 0x00', Puissance Extrieur: 7.00 W
615 [11/04/08 17:27:52:468]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x01', Temprature chambre: 20.56 C
616 [11/04/08 17:28:02:468]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x09 0x00 0x00', Puissance Hall: 137.00 W
617 [11/04/08 17:28:02:531]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x00 0x00 0x00', Puissance Chambre: 8.00 W
618 [11/04/08 17:28:02:531]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xE0 0x00 0x00', Puissance Extrieur: 7.00 W
619 [11/04/08 17:28:14:406]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x11 0x00 0x00', Puissance Hall: 145.00 W
620 [11/04/08 17:28:14:468]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x00 0x00 0x00', Puissance Chambre: 8.00 W
621 [11/04/08 17:28:14:468]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xE0 0x00 0x00', Puissance Extrieur: 7.00 W
622 [11/04/08 17:28:24:093]: GroupDataConfirmationRead: 07/0003, RoutingCnt=6, PriorityLow, No Error
623 [11/04/08 17:28:24:093]: GroupDataIndicationResponse: 01.01.002, 06/0001, RoutingCnt=6, PriorityLow, Data='0x01', Eclairage ON/OFF lampes hall et repas: on
624 [11/04/08 17:28:24:343]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x19 0x00', Temprature chambre: 20.48 C
625 [11/04/08 17:28:26:406]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x11 0x00 0x00', Puissance Hall: 145.00 W
626 [11/04/08 17:28:26:406]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x00 0x00 0x00', Puissance Chambre: 8.00 W
627 [11/04/08 17:28:26:406]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xE0 0x00 0x00', Puissance Extrieur: 7.00 W
628 [11/04/08 17:28:38:281]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x11 0x00 0x00', Puissance Hall: 145.00 W
629 [11/04/08 17:28:38:343]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x40 0x00 0x00', Puissance Chambre: 12.00 W
630 [11/04/08 17:28:38:343]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xE0 0x00 0x00', Puissance Extrieur: 7.00 W
631 [11/04/08 17:28:46:343]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0x83', Luminosit: 11.55 Lux
632 [11/04/08 17:28:47:921]: GroupDataIndicationWrite: 01.01.013, 06/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Variation % lampe repas: 100
633 [11/04/08 17:28:47:984]: GroupDataIndicationWrite: 01.01.013, 13/0602, RoutingCnt=6, PriorityLow, Data='0x00', Inclinaison % lamelles store: 0
634 [11/04/08 17:28:50:296]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x02 0x00 0x00', Puissance Hall: 130.00 W
635 [11/04/08 17:28:50:296]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xE0 0x00 0x00', Puissance Chambre: 7.00 W
636 [11/04/08 17:28:50:421]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0xE0 0x00 0x00', Puissance Extrieur: 7.00 W
637 [11/04/08 17:28:52:671]: GroupDataIndicationWrite: 01.01.014, 13/0602, RoutingCnt=6, PriorityLow, Data='0xFF', Inclinaison % lamelles store: 100
638 [11/04/08 17:28:52:687]: GroupDataIndicationWrite: 01.01.014, 04/0003, RoutingCnt=6, PriorityLow, Data='0x01', Scnario nuit ON/OFF: on
639 [11/04/08 17:28:52:687]: GroupDataIndicationWrite: 01.01.014, 13/0601, RoutingCnt=6, PriorityLow, Data='0xFF', Position % store: 100
640 [11/04/08 17:28:52:734]: GroupDataIndicationWrite: 01.01.002, 06/0203, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampe SAS: on
641 [11/04/08 17:28:54:796]: GroupDataIndicationWrite: 01.01.004, 13/0802, RoutingCnt=6, PriorityLow, Data='0xFF', Info d'tat % inclinaison lamelles: 100
642 [11/04/08 17:28:54:859]: GroupDataIndicationWrite: 01.01.004, 13/0801, RoutingCnt=6, PriorityLow, Data='0xFF', Info d'tat % position store letrique: 100
643 [11/04/08 17:28:58:171]: GroupDataIndicationWrite: 01.01.009, 03/0001, RoutingCnt=6, PriorityLow, Data='0x00', Chauffer ON/OFF: off
644 [11/04/08 17:28:58:171]: GroupDataIndicationWrite: 01.01.009, 08/0001, RoutingCnt=6, PriorityLow, Data='0x00', Ventiler ON/OFF: off
645 [11/04/08 17:29:02:234]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x41 0x00 0x00', Puissance Hall: 193.00 W
646 [11/04/08 17:29:02:234]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x40 0x00 0x00', Puissance Chambre: 12.00 W
647 [11/04/08 17:29:02:296]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x00 0x00 0x00', Puissance Extrieur: 8.00 W
648 [11/04/08 17:29:08:109]: GroupDataIndicationWrite: 01.01.009, 00/0006, RoutingCnt=6, PriorityLow, Data='0x18 0xFF', Temprature chambre: 20.40 C
649 [11/04/08 17:29:14:171]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x42 0x00 0x00', Puissance Hall: 194.00 W
650 [11/04/08 17:29:14:234]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x20 0x00 0x00', Puissance Chambre: 10.00 W
651 [11/04/08 17:29:14:234]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x00 0x00 0x00', Puissance Extrieur: 8.00 W
652 [11/04/08 17:29:26:109]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x45 0x00 0x00', Puissance Hall: 197.00 W
653 [11/04/08 17:29:26:171]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x10 0x00 0x00', Puissance Chambre: 9.00 W
654 [11/04/08 17:29:26:171]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x00 0x00 0x00', Puissance Extrieur: 8.00 W
655 [11/04/08 17:29:38:046]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x42 0x00 0x00', Puissance Hall: 194.00 W
656 [11/04/08 17:29:38:125]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x10 0x00 0x00', Puissance Chambre: 9.00 W
657 [11/04/08 17:29:38:125]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x41 0x00 0x00 0x00', Puissance Extrieur: 8.00 W
658 [11/04/08 17:29:44:218]: EIB connection terminated
659 [11/04/08 17:31:09:906]: EIB connection established
660 [11/04/08 17:31:34:468]: GroupDataConfirmationWrite: 06/0006, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Eclairage ON/OFF lampes lit: on
661 [11/04/08 17:31:35:781]: GroupDataConfirmationWrite: 06/0006, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes lit: off
662 [11/04/08 17:31:35:843]: GroupDataIndicationWrite: 01.01.002, 06/0206, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes lit: off
663 [11/04/08 17:31:37:843]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x8B 0x80 0x00', Puissance Hall: 279.00 W
664 [11/04/08 17:31:37:843]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x40 0x00 0x00', Puissance Chambre: 12.00 W
665 [11/04/08 17:31:37:906]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
666 [11/04/08 17:31:38:281]: GroupDataConfirmationWrite: 06/0006, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Eclairage ON/OFF lampes lit: on
667 [11/04/08 17:31:38:343]: GroupDataIndicationWrite: 01.01.002, 06/0206, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes lit: on
668 [11/04/08 17:31:39:656]: GroupDataConfirmationWrite: 06/0006, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes lit: off
669 [11/04/08 17:31:39:718]: GroupDataIndicationWrite: 01.01.002, 06/0206, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes lit: off
670 [11/04/08 17:31:40:718]: GroupDataConfirmationWrite: 06/0005, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Eclairage ON/OFF lampe chambre: on
671 [11/04/08 17:31:40:718]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampe chambre: on
672 [11/04/08 17:31:44:656]: GroupDataConfirmationWrite: 06/0005, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampe chambre: off
673 [11/04/08 17:31:44:656]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampe chambre: off
674 [11/04/08 17:31:46:781]: GroupDataConfirmationWrite: 06/0005, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Eclairage ON/OFF lampe chambre: on
675 [11/04/08 17:31:46:781]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampe chambre: on
676 [11/04/08 17:31:48:031]: GroupDataConfirmationWrite: 06/0005, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampe chambre: off
677 [11/04/08 17:31:48:031]: GroupDataIndicationWrite: 01.01.003, 06/0205, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampe chambre: off
678 [11/04/08 17:31:48:406]: GroupDataIndicationWrite: 01.01.013, 00/0004, RoutingCnt=6, PriorityLow, Data='0x04 0xA4', Luminosit: 11.88 Lux
679 [11/04/08 17:31:49:843]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x8B 0x80 0x00', Puissance Hall: 279.00 W
680 [11/04/08 17:31:49:843]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x41 0x10 0x00 0x00', Puissance Chambre: 9.00 W
681 [11/04/08 17:31:49:906]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
682 [11/04/08 17:31:49:968]: GroupDataConfirmationWrite: 06/0004, RoutingCnt=6, PriorityLow, Data='0x01', No Error, Eclairage ON/OFF lampes couloir chambre: on
683 [11/04/08 17:31:50:031]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x01', Info d'tat ON/OFF lampes couloir chambre: on
684 [11/04/08 17:31:51:281]: GroupDataConfirmationWrite: 06/0004, RoutingCnt=6, PriorityLow, Data='0x00', No Error, Eclairage ON/OFF lampes couloir chambre: off
685 [11/04/08 17:32:01:781]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x8C 0x80 0x00', Puissance Hall: 281.00 W
686 [11/04/08 17:32:01:843]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x42 0xD0 0x00 0x00', Puissance Chambre: 104.00 W
687 [11/04/08 17:32:01:843]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x80 0x00 0x00', Puissance Extrieur: 4.00 W
688 [11/04/08 17:32:06:343]: GroupDataIndicationWrite: 01.01.002, 06/0204, RoutingCnt=6, PriorityLow, Data='0x00', Info d'tat ON/OFF lampes couloir chambre: off
689 [11/04/08 17:32:13:781]: GroupDataIndicationWrite: 01.01.006, 00/0001, RoutingCnt=6, PriorityHigh, Data='0x43 0x8D 0x00 0x00', Puissance Hall: 282.00 W
690 [11/04/08 17:32:13:843]: GroupDataIndicationWrite: 01.01.006, 00/0002, RoutingCnt=6, PriorityHigh, Data='0x40 0xC0 0x00 0x00', Puissance Chambre: 6.00 W
691 [11/04/08 17:32:13:843]: GroupDataIndicationWrite: 01.01.006, 00/0003, RoutingCnt=6, PriorityHigh, Data='0x40 0x40 0x00 0x00', Puissance Extrieur: 3.00 W
692 [11/04/08 17:32:18:468]: EIB connection terminated